beautypg.com

HP StoreOnce Backup User Manual

Page 133

background image

5.

Register TRAP-DESTINATIONS-MIB.

Still in the Command window, enter the command mxmib —a
TRAP-DESTINATIONS-MIB.cfg

.

6.

Log out from the HP System Insight Manager and then log back in again.

7.

Check that SEMI-MIB and TRAP-DESTINATIONS-MIB have been registered with HP System
Insight Manager by selecting Options — Events — SNMP Trap Settings… on the HP-SIM Home
page.

Scroll down the list of available MIBs to locate SEMI-MIB and TRAP-DESTINATIONS-MIB.

Update the system type database

1.

Log on to HP System Insight Manager, if not already logged on.

2.

Select Options — Manage System Types… on the Home page to display a list of all managed
system types.

3.

Click on New... to add a new system type.

4.

Define a new rule filling only required fields. as follows:

System object identifier: 1.3.6.1.4.1.11.10.3.1.3.27

Compare rule: match

Priority: 1 (highest)

System type: Storage Device

Product Model: HP StorageWorks D2D

SNMP (Configuration)

133