Hp sim support – HP Lights-Out 100 Remote Management User Manual

Page 46

background image

Using LO100 46

Console Redirection: Enabled

Baud Rate: 9600

Terminal Type: VT100+

Flow Control: None

Redirection After BIOS POST: On

4.

Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exit
Setup.

After enabling Windows® EMS management, you can view the Windows® EMS management console

remotely from a client computer through an established telnet session to the IP address of the target server

by pressing the Esc+Q keys. To end an EMS session press the Esc+( keys. See your operating system
documentation for instructions on establishing telnet sessions.

NOTE:

If you encounter problems logging in to the remote console, be aware that some telnet

programs might require you to enable their

send line feed at end of line

option. If

the remote console does not respond to the Enter key, try setting this option in your telnet

program.

HP SIM support

HP SIM discovers LO100 and enables you to identify and launch LO100. See your HP SIM user guide for

more information on using HP SIM with LO100.