Avaya 3600 User Manual
Page 57
Avaya, Inc.
Configuration and Administration—AVAYA 3616/3620/3626 WT
Avaya CCMS IP, Avaya Call Server, with Avaya 4612 IP Telephone Emulation
21-300352, Issue 2, July 2005
Page 57
Message Description
Action
Extension Error
Displayed for 5 seconds when all of
the Call Servers contacted indicate
that they do not recognize the
current extension as valid.
The user will be asked to enter a
valid extension and password
Extension in Use
The phone is trying to register with
an extension that is already
registered on the Call Server.
See Avaya Call Server Integration
Factors section.
Files Too Big
WT software download files are
incorrect or corrupted
Download new software from the
OEM site per Software
Maintenance.
Flash Config Error
WT internal configuration is corrupt.
Perform "Restore Defaults"
operation via administrator menus
[or reprogram with Configuration
Cradle]
Gatekeeper REJ
Gatekeeper rejected Discovery
Request from the WT
Check the H.323 gatekeeper
configuration in the WT.
Verify the gatekeeper or PBX’s
configuration
H225 Listen Fail
WT cannot communicate with the AP
or the AVPP
This message may display with
another diagnostic message.
Follow diagnostic actions for the
second message (such as No Net
Found).
H245 Listen fail
WT cannot communicate with the AP
or the AVPP
This message may display with
another diagnostic message.
Follow diagnostic actions for the
second message (such as No Net
Found).
Incompatible
The switch is rejecting the software
version presented by the phone.
If this condition persists, contact
the Avaya system administrator.
Initializing …
The WT is performing power on
initialization
None. This is informational only.
Internal Err. # #
The WT has detected a fault from
which it cannot recover.
OE = Error while writing the Flash
(return WT to factory)
OF = No functional code (contact
OEM Technical Support)
Record the error code so it can be
reported.
Turn the WT off then on again.
If error persists, try registering a
different WT to this telephone port.
If error still persists, contact OEM
Technical Support and report the
error.
Invalid Revision
Gatekeeper rejected registration
request from the WT
Verify the gatekeeper or PBX’s
configuration. Ensure the
gatekeeper and PBX will support
version 2 of the H.323 protocol.