4.4.10 Timer setting mode
Character
PV screen
Auxiliary screen
Designation
Description
Initial value
1
□
□□□□
Select the timer
Setting concerning the timer
2
□
Set a timer
function
: Auto-start
: Manual start
: Event start
: SV start (OFF delay only)
Setting a value for the ON delay timer to be mentioned
below will activate it as an ON delay timer.
Setting a repetition frequency activates the timer as a
repetition timer. At that time, repetition will not be
activated unless an ON or OFF delay timer is set.
3
□
Set a timer unit
: Hours and minutes
: Minutes and seconds
4
□
Set a start
tolerance for the
timer SV
Thermocouple input
Setting range: 0 to 999 or 0.0 to 999.9
Setting unit:
°C
Resistance bulb input
Setting range: 0 to 999 or 0.0 to 999.9 or 0.00 to
999.99
(when the input type is ,,
or )
Setting unit:
°C
Current and voltage inputs
Setting range: 0 to 99999
The decimal place can be set to a
desired position.
Setting unit:
digit
CH2 only
Potentiometer input
Setting range: 0.0 to 999.9
Setting unit:
%
* If the timer is used, set a connection channel with P45 or P50 .