4.4.6 OUT 1 to 6 setting mode

Character

PV screen
Auxiliary screen

Designation

Description

Initial value

1

□
□□□□
to
□
□□□□

Select OUT 1 to
OUT 6

Setting concerning outputs 1 to 6

2

□

to
□


Set an OUT 1
function to OUT 6
function

Output connection channel
: Connect it to CH1
: Connect it to CH2 (displayed when CH2 is

available)


Type of output connection port
: Connect it to the main output (an open signal

in the case of potentiometer input)

: Connect it to the auxiliary output (a closed

signal in the case of potentiometer input)

: Connect it to the event
: Connect it to transmission (displayed when the

output is analog)


* For open and close signals for the position

proportional control with a potentiometer, set the
output connection channel to 2CH.

* This has no transmission functions in  and

.

In the case of
509-0N
_O1F/_O2F
/
_O3F/_O6F

In the case of
509-00
_O1F/_O2F
/
_O3F/_O6F


3

□

to
□


Set a function for
event output 1 to 6

(PV event)

Display color switchover
: The PV display color remains unchanged

even if the PV event is turned on.

: The PV display color changes if the PV

event is turned on.


Additional functions
: Disabled
: Hold
: Standby sequence
: Hold + standby sequence

PV event functions
: Disabled
: Deviation upper and lower limit
: Deviation upper limit
: Deviation lower limit
: Deviation range
: Upper and lower limit
: Upper limit
: Lower limit
: Range
: Connect to timer

