Syntax, Relpresscal.a0[=n, Relpresscal.a1[=n – ROTRONIC MBW 373 User Manual
Page 46: Relpresscal.a2[=n, Relpresscal.a3[=n, Relpresscal.avg[=n, Relpresscal.avgband[=i, Relpresscal.senscode[=i, Relpresscal.coeftype[=i, Flow sensor calibration coefficients
42
Relative Pressure Sensor Calibration Coefficients (if so equipped)
Syntax Function
RelPressCal.a0[=n][?]
Polynomial 0
th
order (Zero) coefficient
RelPressCal.a1[=n][?]
Polynomial 1
st
order (Span) coefficient
RelPressCal.a2[=n][?]
Polynomial 2
nd
order (Linearity) coefficient
RelPressCal.a3[=n][?]
Polynomial 3
rd
order (Linearity2) coefficient
RelPressCal.avg[=n][?]
Amount of averaging applied to measurement,
~100
RelPressCal.avgBand[=i][?]
Only average when measurements remain within
this band, ~ 1000 Pa
RelPressCal.sensCode[=i][?]
=21 for voltage output sensor
RelPressCal.coefType[=i][?]
=2 for polynomial type coefficients
SaveCal=373
Save these and other calibration parameters
Flow Sensor Calibration Coefficients
Syntax Function
FlowCal.a0[=n][?]
Polynomial 0
th
order (Zero) coefficient
FlowCal.a1[=n][?]
Polynomial 1
st
order (Span) coefficient
FlowCal.a2[=n][?]
Polynomial 2
nd
order (Linearity) coefficient
FlowCal.a3[=n][?]
Polynomial 3
rd
order (Linearity2) coefficient
FlowCal.avg[=n][?]
Amount of averaging applied to measurement, ~0
FlowCal.avgBand[=i][?]
Only average when measurements remain within
this band, ~ 0 l/m
FlowCal.sensCode[=i][?]
=21 for voltage output sensor
FlowCal.coefType[=i][?]
=2 for polynomial type coefficients
SaveCal=373
Save these and other calibration parameters
System Identification
Syntax Function
ID?
Returns a string containing instrument
identification, ie. DPM 373LX
IDN?
Returns only numeric portion of identifier, ie. 373
Saving Changes
Syntax Function
SaveCfg=373
Save configuration parameters
SaveCal=373
Save calibration parameters
SavePID=373
Save PID parameters