5 Settings and displays
BU 0070 GB
Subject to technical alterations
21
5.3 LED display
The status of the InterBus technology unit is shown by 5(6) LED's :
• UL (green):
Supply voltage applied
• RC (green):
RemoteCheck
• BA (green):
Bus Active
• RD (yellow):
Remotebus Disabled
• TR
(green): Transmit
2-colour LED
• ST
(green): Module
status
• ST (red):
Module error
UL (green): InterBus power supply
Display
Meaning
Off
No power supply
On
InterBus power supply OK
RC (green): InterBus RemoteCheck
Display
Meaning
Off
Remote bus to previous subscriber interrupted
- check corresponding cable connection
On
Remote bus to previous InterBus device OK
BA (green): Bus Active
Display
Meaning
Off
InterBus in stop state
On
InterBus data is
being exchanged
RD (yellow): RemoteBus Disabled
Display
Meaning
Off
Remote bus to next InterBus device OK
On
Remote bus to next InterBus device disabled
- check corresponding cable connection
TR (green): Transmit
Display
Meaning
Off
No communication at the moment
On
Communication telegrams are being transmitted to the access module