5 kw to 7.5 kw, Table 20: 1.5 kw – NORD Drivesystems MI0700 User Manual
Page 38
Frequency inverters
– Migration Guide SK 700E to SK 5xxE
38
MI 0700 GB-0414
Pos : 44 /Migrati onsl eitf aden/ SK 700E - SK 500E/2. U ms etz ung/ 2. 6. 1 U nt erbau- Netzfilt er und U nt erbau- Kombi- N etz filter @ 3\ mod_1362412213845_388. doc x @ 61066 @ 355 @ 1
2.6.1 Footprint mains filters and footprint combination mains filters
The footprint (UB)- mains filters SK LFx-4x0/xx-F and the combined footprint combination mains
filters SK NHD-480/xx-F differ by the additional integrated mains input choke. The following tables list
and compare the various footprint mains filters allocated to each of the performance levels. Both
mains filters come in protection class IP20 and can be fitted as footprint and also as book size
components. Mains connection to the mains filters occurs with screw terminals. Depending on the
cable type (shielded or unshielded) and the length of the motor cable, both footprint mains filters
feature a radio interference suppression level Class B or C1 with a maximum motor cable length of
50 m and a shielded cable. For a maximum motor cable length of 100 m and shielded motor cable,
both footprint mains filters comply with EMC limit value classes A or C2.
1.5 kW to 7.5 kW
Footprint mains filter
SK LF1-460/xx-F
Part No.
Name
Information
Data
Footprint combination
mains filter
SK NHD-480/xx-F
Part No.
SK LF1-460/14-F
278271014
Footprint mains filter / footprint
combination mains filter
•
Power 1.5 kW and 2.2 kW
•
Class 3 (B)
SK NHD-480/6-F
278273006
Footprint mains filter / footprint
combination mains filter
•
Power 3.0 kW and 4.0 kW
•
Class 3 (B)
SK NHD-480/10-F
278273010
SK LF1-460/24-F
278271024
Footprint mains filter / footprint
combination mains filter
•
Power 5.5 kW and 7.5 kW
•
Class 3 (B)
SK NHD-480/16-F
278273016
Table 20: 1.5 kW
– 7.5 kW footprint mains filter and footprint combination mains filter