Pos : 19 /Migrati onsl eitf aden/ SK 700E - SK 500E/2. U ms etz ung/ 2. 1. 1. Perfor mance- St uf en @ 2\ mod_1357222355717_388. doc x @ 52870 @ 3 @ 1
2.1.1 Performance levels
SK 700E
SK 700E
Features /
Performance range
SK 5xxE
Name
Name
SK 700E-xxx-340-X (-RS2) *
Standard
Performance 1.5 kW to 7.5 kW
+ incl. mains filter *
+ optional with int. RS232 interface *
SK 500E-xxx-340-A
incl. mains filter Class C2 **
+ RS232 interface
Standard
Performance 11.0 kW to 160.0 kW
+ with/without mains filter *
+ optional / with int. RS232 interface *
SK 515E-xxx-340-A
with mains filter Class C2 **
+ RS232 interface
SK 700E-xxx-340-X (-RS2) *
+ ENCODER
SK XU1-ENC
Standard
Performance 1.5 kW to 7.5 kW
+ incl. mains filter *
+ optional with int. RS232 interface *
+ 1 TTL input for incremental encoder
+ 1 digital input
SK 520E-xxx-340-A
with mains filter Class C2 **
+ RS232 interface
Standard
Performance 11.0 kW to 160.0 kW
+ with/without mains filter *
+ optional / with int. RS232 interface *
+ 1 TTL input for incremental encoder
+ 1 digital input
SK 535E-xxx-340-A
with mains filter Class C2 **
+ RS232 interface
*
(-RS2) with additional optional/integrated RS232 interface on SK
700E frequency inverters ≤ 22.0 kW.
The token X represents A (with integrated mains filter) on SK
700E frequency inverters ≤ 22.0 kW
O (without integrated mains filter) on SK
700E frequency inverters ≥ 30.0 kW
**
The cable lengths must be taken into account because the mains filter characteristics can vary.
Table 4: Overview SK 5xxE standard and incremental encoder input
NOTICE
Encoder supply voltage
Incremental encoders with 5 V supply voltage can be directly operated with frequency inverters of the SK 700E
series. For the SK 5xxE series of frequency inverters, the connected incremental encoders must be suitable for a
supply voltage range of 10
V … 30 V.
This is why the incremental encoders must be replaced or the "old" encoders must be supplied from an external
power supply when migrating to SK 5xxE frequency inverters.