Frequency inverters

– Migration Guide SK 700E to SK 5xxE

16

MI 0700 GB-0414

2.1 Frequency inverter

Pos : 19 /Migrati onsl eitf aden/ SK 700E - SK 500E/2. U ms etz ung/ 2. 1. 1. Perfor mance- St uf en @ 2\ mod_1357222355717_388. doc x @ 52870 @ 3 @ 1

2.1.1 Performance levels

SK 700E

SK 700E

Features /

Performance range

SK 5xxE

Name

Name

SK 700E-xxx-340-X (-RS2) *

Standard

Performance 1.5 kW to 7.5 kW

+ incl. mains filter *

+ optional with int. RS232 interface *

SK 500E-xxx-340-A

incl. mains filter Class C2 **

+ RS232 interface

Standard

Performance 11.0 kW to 160.0 kW

+ with/without mains filter *

+ optional / with int. RS232 interface *

SK 515E-xxx-340-A

with mains filter Class C2 **

+ RS232 interface

SK 700E-xxx-340-X (-RS2) *

+ ENCODER

SK XU1-ENC

Standard

Performance 1.5 kW to 7.5 kW

+ incl. mains filter *

+ optional with int. RS232 interface *

+ 1 TTL input for incremental encoder

+ 1 digital input

SK 520E-xxx-340-A

with mains filter Class C2 **

+ RS232 interface

Standard

Performance 11.0 kW to 160.0 kW

+ with/without mains filter *

+ optional / with int. RS232 interface *

+ 1 TTL input for incremental encoder

+ 1 digital input

SK 535E-xxx-340-A

with mains filter Class C2 **

+ RS232 interface

*

(-RS2) with additional optional/integrated RS232 interface on SK

700E frequency inverters ≤ 22.0 kW.

The token X represents A (with integrated mains filter) on SK

700E frequency inverters ≤ 22.0 kW

O (without integrated mains filter) on SK

700E frequency inverters ≥ 30.0 kW

**

The cable lengths must be taken into account because the mains filter characteristics can vary.

Table 4: Overview SK 5xxE standard and incremental encoder input

NOTICE

Encoder supply voltage

Incremental encoders with 5 V supply voltage can be directly operated with frequency inverters of the SK 700E
series. For the SK 5xxE series of frequency inverters, the connected incremental encoders must be suitable for a
supply voltage range of 10

V … 30 V.

This is why the incremental encoders must be replaced or the "old" encoders must be supplied from an external
power supply when migrating to SK 5xxE frequency inverters.