Frequency inverters
– Migration Guide SK 700E to SK 5xxE
20
MI 0700 GB-0414
SK 700E
SK 700E
Features /
Performance range
SK 5xxE
Name
Name
see previous page
+ plus
IO customer unit
SK CU1-xxx ****
Standard
Performance 1.5 kW to 7.5 kW
+ incl. mains filter *
+ optional with int. RS232 interface *
plus I/O control connections of the
respective SK CU1-xxx customer unit
SK 540E-xxx-340-A
with mains filter Class C2 **
+ RS232 interface
optional
IO extension
SK EBIOE-2 *****
Standard
Performance 11.0 kW to 22.0 kW
+ incl. mains filter *
+ optional with int. RS232 interface *
plus I/O control connections of the
respective SK CU1-xxx customer unit
SK 545E-xxx-340-A
with mains filter Class C2 **
+ RS232 interface
optional
IO extension
SK EBIOE-2 *****
Standard
Performance 30.0 kW to 160.0 kW
+ without mains filter *
+ integrated RS232 interface *
plus I/O control connections of the
respective SK CU1-xxx customer unit
*
(-RS2) with additional optional/integrated RS232 interface on SK
700E frequency inverters ≤ 22.0 kW.
The token X represents A (with integrated mains filter) on SK
700E frequency inverters ≤ 22.0 kW
O (without integrated mains filter) on SK
700E frequency inverters ≥ 30.0 kW
**
The cable lengths must be taken into account because the mains filter characteristics can vary.
****
Plus one of the following IO customer units:
SK CU1-BSC, SK CU1-STD, SK CU1-MLT or SK CU1-MLT-20mA.
*****
When using a great number of digital control signals (number of used (from SK 700E + option) and available (SK
5xxE) digital inputs. The IO extension SK EBIOE-2 (275900210) can only be connected to SK 540E and SK 545E
frequency inverters.
Table 6: Overview of SK 5xxE performance levels for POSICON positioning control
NOTICE
Encoder supply voltage
Incremental encoders with 5 V supply voltage can be directly operated with frequency inverters of the SK 700E
series. For the SK 5xxE series of frequency inverters, the connected incremental encoders must be suitable for a
supply voltage range of 10
V … 30 V.
This is why the incremental encoders must be replaced or the "old" encoders must be supplied from an external
power supply when migrating to SK 5xxE frequency inverters.