beautypg.com

Notice, Encoder supply voltage – NORD Drivesystems MI0700 User Manual

Page 20

background image

Frequency inverters

– Migration Guide SK 700E to SK 5xxE

20

MI 0700 GB-0414

SK 700E

SK 700E

Features /

Performance range

SK 5xxE

Name

Name

see previous page

+ plus

IO customer unit
SK CU1-xxx ****

Standard

Performance 1.5 kW to 7.5 kW

+ incl. mains filter *

+ optional with int. RS232 interface *

plus I/O control connections of the
respective SK CU1-xxx customer unit

SK 540E-xxx-340-A
with mains filter Class C2 **
+ RS232 interface

optional

IO extension
SK EBIOE-2 *****

Standard

Performance 11.0 kW to 22.0 kW

+ incl. mains filter *

+ optional with int. RS232 interface *

plus I/O control connections of the
respective SK CU1-xxx customer unit

SK 545E-xxx-340-A
with mains filter Class C2 **
+ RS232 interface

optional

IO extension
SK EBIOE-2 *****

Standard

Performance 30.0 kW to 160.0 kW

+ without mains filter *

+ integrated RS232 interface *

plus I/O control connections of the
respective SK CU1-xxx customer unit

*

(-RS2) with additional optional/integrated RS232 interface on SK

700E frequency inverters ≤ 22.0 kW.

The token X represents A (with integrated mains filter) on SK

700E frequency inverters ≤ 22.0 kW

O (without integrated mains filter) on SK

700E frequency inverters ≥ 30.0 kW

**

The cable lengths must be taken into account because the mains filter characteristics can vary.

****

Plus one of the following IO customer units:

SK CU1-BSC, SK CU1-STD, SK CU1-MLT or SK CU1-MLT-20mA.

*****

When using a great number of digital control signals (number of used (from SK 700E + option) and available (SK
5xxE) digital inputs. The IO extension SK EBIOE-2 (275900210) can only be connected to SK 540E and SK 545E
frequency inverters.

Table 6: Overview of SK 5xxE performance levels for POSICON positioning control

NOTICE

Encoder supply voltage

Incremental encoders with 5 V supply voltage can be directly operated with frequency inverters of the SK 700E
series. For the SK 5xxE series of frequency inverters, the connected incremental encoders must be suitable for a
supply voltage range of 10

V … 30 V.

This is why the incremental encoders must be replaced or the "old" encoders must be supplied from an external
power supply when migrating to SK 5xxE frequency inverters.