beautypg.com

9 error messages, 1 table of possible error messages, 2 error display – NORD Drivesystems BU0230 User Manual

Page 67

background image

9 Error messages

BU 0230 GB-2712

67

9 Error messages

Basic information on this topic is contained in the operating manual BU 0200 GB. The following section
describes the error messages, which are assigned to functional safety.

9.1 Table of possible error messages

Display in the
SimpleBox

Fault

Text in the ParameterBox

Cause

Remedy

Group

Details in
P700 / P701

E008

8.0

Parameter loss
(maximum EEPROM value
exceeded)

Error in EEPROM data

Software version of the stored data set not compatible with
the software version of the FI.

Note:

Faulty parameters are automatically reloaded
(factory setting).

EMC interferences (see also E020)

8.1

Inverter type incorrect

EEPROM faulty

8.2

External copying error

--

8.3

EEPROM KSE error

(Customer interface
incorrectly identified
(customer’s interface
equipment))

The upgrade level of the frequency inverter was not
correctly identified.

EEPROM with a firmware status of version 1.2 or above
plugged in to an FI with older firmware status → Loss of
parameters!

Switch mains voltage off and on again.

8.4

Internal EEPROM error

(Database version incorrect)

8.7

EEPR copy not the same

E018

18.0

Safety circuit

The safety circuit -safe pulse block- triggered while the
frequency inverter was being enabled.

Only available in SK 210E, SK 215E, SK 230E and SK 235E

NOTE

If a parameter loss occurs during operation of the frequency inverter (Error 8.0), the safety-
relevant parameters must be checked and a validation of the safety function must be
performed. This particularly applies if the memory module (external EEPROM) is replaced.

9.2 Error display

Frequency inverter: The error number is displayed as a flashing code of the status LED DS (Drive Status) in
"red".

SimpleBox: The SimpleBox indicates a fault with its number and the prefix "E". If the cause of the error is no
longer present, the error display in the SimpleBox flashes and the error can be acknowledged with the Enter
key.

ParameterBox: The error messages are shown in plain text.