3 Assembly and installation

BU 0230 GB-2712

41

LABELLING, FUNCTION

SH:

"Safe stop" function„

ASI:

Integrated AS interface

24V:

24V power supply

AGND:

Reference potential for analogue
signals

GND:

Reference potential for digital
signals

DIN:

Digital input

DOUT:

Digital output

24V SH: "Safe stop" input

GND SH: "Safe stop" reference potential

SYS+/-:

System bus

MB+/-:

Electromagnetic brake control
(105V, 180V, 205V)

TF+/-:

Motor PTC connection

CONNECTIONS AND FUNCTIONS FOR SK 2XXE VERSIONS DEPENDING ON CONFIGURATION LEVEL

Size 1 to 3

SK 200E SK 210E

SK 220E

SK 230E

FI type

SK 205E

SK 215E SK 225E

SK 235E

(SH)

(ASI)

(SH+ASI)

Labelling

(SH)

(ASI)

(SH+ASI)

X2:

Pin

X2:

24V (internal, output max. 200mA)

44

1

44

24V, external 24V FI supply*

Analog input 1

ASI+, AS interface

14/84

2

44/84

24V, external 24V

FI supply

ASI+, AS interface

Analog input 2

16

3

40

GND, reference potential for digital signals

AGND, Reference

potential for analog

signals

ASI-, AS interface

12/85

4

40/85

GND

ASI-, AS interface

DIN1 / digital input 1

21

5

21

DIN1 / digital input 1

DIN2 / digital input 2

22

6

22

DIN2 / digital input 2

DIN3, digital input 3

23

7

23

DIN3, digital input 3

DIN4,

digital

input 4

24V SH,

“Safe
stop”„

DIN4,

digital

input 4

24V SH,

“Safe
stop”„

24/89

8

24/89

DIN4,

digital

input 4

24V SH,

“Safe
stop”„

DIN4,

digital

input 4

24V SH,

“Safe
stop”„

GND

GND SH

GND

GND SH

40/88

9

40/88

GND

GND SH

GND

GND SH

DOUT1, digital output 1

1

10

1

DOUT1, digital output 1

GND

40

11

40

GND

SYS H, system bus +

77

12

77

SYS H, system bus +

SYS L, system bus -

78

13

78

SYS L, system bus -

10V Reference voltage

11

14

-

---

DOUT2, digital output 2

3

15

79

MB+, electromagnetic brake control

GND

40

16

80

MB-, electromagnetic brake control

TF+, motor PTC connection

38

17

38

TF+, motor PTC connection

TF-, motor PTC connection

39

18

39

TF-, motor PTC connection

*With the use of the AS interface, terminal 44 provides an output voltage (24V, max. 60mA). In this case, no voltage sources may be connected to this
terminal!

NOTE

GND is a common reference potential for digital inputs and outputs and for the 24V supply of
the frequency inverter.

The labelling of the control terminal bar differs according to the SK 200E version.