beautypg.com

4 emc, 7 digital inputs, 1 details of the digital inputs – NORD Drivesystems BU0230 User Manual

Page 47: Ql r, Km mm, 5 . 0 r, Number r

background image

3 Assembly and installation

BU 0230 GB-2712

47

q

l

R

CU

*

with

km

mm

CU

*

19

Double the length of cable must be used because line drops occur in both wires.

5

.

0

R

or

3

*

FI

Number

R

=> for a digital output without load, an input voltage of at least 22V is required.

3.6.4

EMC

With EMC-compliant wiring, the EMC guideline values (see BU 0200 GB) can be complied with up to a cable
length of 100m between the sprotective switching device and the inverter.

3.7 Digital inputs

3.7.1

Details of the digital inputs

Terminal/

Name

Function

[factory setting]

Data

Description / wiring suggestion

Parameter


SK 200E, SK 205E, SK 210E, SK 215E, SK220E, SK 225E, SK 230E, SK 235E

40

GND

Reference potential
for digital signals

0 V digital

Reference potential

-

21

DIN1

Digital input 1

[ON right]

Digital input as per
EN 61131-2 Type 1

Low: 0

-5 V

(~ 9.5 k

Ω)

High: 15-30 V

(~ 2.5-3.5 k

Ω)

Input capacitance:
Input 1 + 4 = 10 nF
Input 2 + 3 = 1.2 nF

Scan time: 1 ms

Reaction time:

≥ 4 ms

P420 [-01]

22

DIN2

Digital input 2

[ON left]

P420 [-02]

23

DIN3

Digital input 3

[Fixed frequency 1],

→ P465[-01]

P420 [-03]


only with SK 200E, SK 205E, SK220E, SK 225E

24

DIN4

Digital input 4

[Fixed frequency 2],

→ P465[-02]

see 21 DIN1

P420 [-04]