BU 0230 GB-2712
Parameter
[factory setting]
Setting value / Description / Note
Device
Supervisor
Parameter
set
P481
... [-01]
...
... [-10]
Function Bus I/O Out Bits
0 ... 39
{ [-01] = 18 }
{ [-02] = 08 }
{ [-03] = 30 }
{ [-04] = 31 }
{ [-05...-10] = 00 }
The bus I/O Out bits are perceived as multi-function relay outputs. They can be set to the same
functions (P434).
These I/O bits can also be used in combination with the AS interface (SK 22xE or SK 23xE)
(Bit 0 … 3) or the I/O extensions (SK xU4-IOE) (Bit 4 … 5 and flags 1 … 2).
[-01] = Bus / AS-i Dig Out1
(Bus IO Out Bit 0 + AS-i 1)
[-02] = Bus / AS-i Dig Out2
(Bus IO Out Bit 1 + AS-i 2)
[-03] = Bus / AS-i Dig Out3
(Bus IO Out Bit 2 + AS-i 3)
[-04] = Bus / AS-i Dig Out4
(Bus IO Out Bit 3 + AS-i 4)
[-05] = Bus / IOE Dig Out1
(Bus IO Out Bit 4 + DO 1 of the first SK xU4-IOE (DigOut 02))
[-06] = Bus / IOE Dig Out2
(Bus IO Out Bit 5 + DO 2 of the first SK xU4-IOE (DigOut 03))
[-07] = Bus / 2nd IOE Dig Out1
(Flag1 + DO 1 of the second SK xU4-IOE (DigOut 04))
[-08] = Bus / 2nd IOE Dig Out2
(Flag2 + DO 2 of the second SK xU4-IOE (DigOut 05))
[-09] = Bit 10 BUS status word
[-10] = Bit 13 BUS status word
The possible functions for the bus Out bits can be found in the table of functions for the digital
output (P434).
P482
[-01]
...
[-10]
Standardisation of bus I/O Out bits
-
400 … 400 %
[ all 100 ]
Adjustment of the limit values of the bus Out bits. For a negative value, the output function will
be output negative.
Once the limit value is reached and positive values are delivered, the output produces a High
signal, for negative setting values a Low signal.
[-01] = Bus / AS-i Dig Out1
(Bus IO Out Bit 0 + AS-i 1)
[-02] = Bus / AS-i Dig Out2
(Bus IO Out Bit 1 + AS-i 2)
[-03] = Bus / AS-i Dig Out3
(Bus IO Out Bit 2 + AS-i 3)
[-04] = Bus / AS-i Dig Out4
(Bus IO Out Bit 3 + AS-i 4)
[-05] = Bus / IOE Dig Out1
(Bus IO Out Bit 4 + DO 1 of the first SK xU4-IOE (DigOut 02))
[-06] = Bus / IOE Dig Out2
(Bus IO Out Bit 5 + DO 2 of the first SK xU4-IOE (DigOut 03))
[-07] = Bus / 2nd IOE Dig Out1
(Flag1 + DO 1 of the second SK xU4-IOE (DigOut 04))
[-08] = Bus / 2nd IOE Dig Out2
(Flag2 + DO 2 of the second SK xU4-IOE (DigOut 05))
[-09] = Bit 10 BUS status word
[-10] = Bit 13 BUS status word