NORD Drivesystems BU0230 User Manual
Page 57
4 Parameterisation
BU 0230 GB-2712
57
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P741
[-01]
...
[-10]
Process data Bus Out
S
0000 ... FFFF (hex)
This parameter provides information about the actual status word and the actual values that are
transferred via the bus systems.
[-01] = Status word
Status word
[-02] = Actual value 1 (P543 [-01])
[-03] = Actual value 2 (P543 [-02])
[-04] = Actual value 3 (P543 [-03])
[-05] = resulting Out bit state P481
The displayed value depicts all bus Out bit
sources linked with OR.
[-06] = Parameter data 1
[-07] = Parameter data Out 2
[-08] = Parameter data Out 3
[-09] = Parameter data Out 4
[-10] = Parameter data Out 5
Data during parameter transfer.
P749
Status DIP switches
0000 ... 01FF
(hex)
or
0 ... 511
(dec)
Bit 8: from SW1.3
This parameter shows the current setting of the FI DIP switch.
Bit 0:
Bit 1:
Bit 2:
Bit 3:
Bit 4:
Bit 5:
Bit 6:
Bit 7:
Bit 8:
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
DIP switch 5
DIP switch 6
DIP switch 7
DIP switch 8
EEPROM (memory module)
Bit 8 = 0: plugged in / Bit 8 = 1: not plugged in