NORD Drivesystems BU0230 User Manual
Page 55
4 Parameterisation
BU 0230 GB-2712
55
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
Note
SimpleBox: with the Simplebox only warning messages and errors can be displayed. Display of
the messages is in encoded form. For the description of the codes (warning/error numbers),
please refer to the tables in BU 0200.
ParameterBox: with the ParameterBox the messages are displayed in plain text.. In addition, the
reason for a possible disabling of starting can also be displayed.
Bus: The display of bus-level error messages is made in decimal integer format. If this value is
divided by 10, the display corresponds to that which is listed in BU 0200.
Example: Display: 20
→ Error number 2.0
P701
[-01]
...
[-05]
Last fault 1...5
0.0 ... 21.4
This parameter stores the last 5 faults. Further details in Section 9.3 .
With the SimpleBox the corresponding memory location 1...5 (Array parameter), must be