NORD Drivesystems BU0230 User Manual
Page 42
Functional safety with NORD SK 200E frequency inverters
42
BU 0230 GB-2712
Size 4
FI type
SK 200E
SK 210E
SK 220E
SK 230E
(SH)
(ASI)
(SH+ASI)
Pin
Labelling
1
43
24V (internal, output max. 750mA)
2
43
24V (internal, output max. 750mA)
3
40
GND, reference potential for digital signals
4
40
GND, reference potential for digital signals
5
-/84
/
ASI+, AS interface
6
-/85
/
ASI-, AS interface
7
11
10V Reference voltage
8
14
Analog input 1
9
16
Analog input 2
10
12
AGND, Reference potential for analog signals
11
44
24V, external 24V FI supply
12
44
24V, external 24V FI supply
13
40
GND, reference potential for digital signals
14
40
GND, reference potential for digital signals
15
21
DIN1 / digital input 1
16
22
DIN2 / digital input 2
17
23
DIN3, digital input 3
18
24/89
DIN4,
digital
input 4
24V SH,
“Safe
stop”„
DIN4,
digital
input 4
24V SH,
“Safe
stop”„
19
40/88
GND
GND SH
GND
GND SH
20
40
GND, reference potential for digital signals
21
1
DOUT1, digital output 1
22
40
GND
23
3
DOUT2, digital output 2
24
40
GND
25
77
SYS H, system bus +
26
78
SYS L, system bus -
27
38
TF+, motor PTC connection
28
39
TF-, motor PTC connection
Separate terminal block (2-pole):
1
79
MB+, electromagnetic brake control
2
80
MB-, electromagnetic brake control
NOTE
GND is a common reference potential for digital inputs and outputs and for the 24V supply of
the frequency inverter.
The labelling of the control terminal bar differs according to the SK 200E version.