NORD Drivesystems BU0210 User Manual
Page 42
SK 2x5E with "PosiCon Functionality"
42
Subject to technical amendments
BU 0210 GB
Information:
Parameters
Setting value / Description / Note
Device
Supervisor
Parameter
set
P744 Configuration
0000 ... FFFF (hex)
This parameter displays the special devices integrated in the FI. Display is in hexadecimal code
(SimpleBox, ControlBox, Bus System).
The display is in plain text when the ParameterBox is used.
High byte:
Low byte:
00
hex
01
hex
02
hex
03
hex
No extension
Encoder
Posicon
---
00
hex
01
hex
02
hex
03
hex
Standard I/O
(SK 205E)
STO
(SK
215E)
AS-i
(SK
225E)
STO and AS-i
(SK 235E)
P748
System bus status
0000 ... FFFF (hex)
or
0 ... 65535 (dec)
Shows the status of the system bus.
Bit 0
Bit 1
Bit 2
Bit 3 ... 5:
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
24V Bus supply voltage
CANbus in "Bus Warning" status
CANbus in "Bus Off" status
Vacant
The protocol of the CAN module is 0 = CAN / 1 = CANopen
Vacant
"Bootsup Message" sent
CANopen NMT State
CANopen NMT State
CANopen NMT State Bit 10 Bit 9
Stopped
Pre-Operational
Operational
0
0
1
0
1
0