NORD Drivesystems BU0210 User Manual
Page 32
SK 2x5E with "PosiCon Functionality"
32
Subject to technical amendments
BU 0210 GB
Control terminals:
Parameters
[factory setting]
Setting value / Description / Note
Device
Supervisor
Parameter set
P420
[-01]
…
[-03]
Function of digital inputs 1 to 4
0 ... 72
[-01 = 1 ]
[-02 = 2 ]
[-03 = 4 ]
[-04 = 5 ]
In the SK 200E, up to 4 freely programmable digital inputs are available. The only restriction is
with the versions SK 215E and SK 235E. Here, the fourth digital input is always the input for the
function “Safe Stop”.
[-01] = Digital input 1
(DIN1), Enable right as factory setting, control terminal 21
[-02] = Digital input 2
(DIN2), Enable left as factory setting, Control terminal 22
[-03] = Digital input 3
(DIN3), Fixed frequency 1 (P465 [-01]) as factory setting,
control terminal 23
[-04] = Digital input 4
(DIN4), Fixed frequency 2 (P465 [-02]) as factory setting,
not with SK 215/235E "Safe Stop", control terminal 24
Various functions can be programmed. These can be seen in the following table.
Table of possible functions of the digital inputs P420 [01]...[03]
Caution:
Only the functions relevant to PosiCon are listed here.
Value
Function
Description
Signal
22
Reference point run
See Section 3.2.1.1
High
23
Reference point
See Section 3.2.1.1
High
24
Teach-In
See Section 3.4
High
25
Quit Teach -In
See Section 3.4
High
55
Bit 0 position (increment) array
See Section 3.3
High
56
Bit 1 position (increment) array
See Section 3.3
High
57
Bit 2 position (increment) array
See Section 3.3
High
58
Bit 3 position (increment) array
See Section 3.3
High
61
Reset position
See Section 3.2.1.2
High
62
Sync for position array pointer
See Section 3.3.1
High
63
Switch off synchronous running
See Section 6
High
NOTE:
For further information please refer to Manual SK 200E, BU0200.