4 Parameter settings
BU 0210 GB
Subject to technical amendments
39
Parameters
[factory setting]
Setting value / Description / Note
Device
Supervisor
Parameter
set
P608
[-01]
…
[-03]
Reduction ratio
S
1...65000
[ 1 ]
[01] =
Incremental encoder
[02] =
Absolute encoder
[03] =
Setpoint and actual values
The speed ratio is set for incremental and absolute encoders.
NOTE:
For further details please refer to Section 3.5
P609
... - 01
... - 02
Offset Position
S
-50000...50000,000 rev
[ 0 ]
Offset for absolute and relative position specifications
[01] =
Incremental encoder
[02] =
Absolute encoder
Here, the offset position for absolute and incremental encoders can be
specified separately for both types of encoder.
P610
Setpoint Mode
S
0 ... 4
[ 0 ]
Various methods are available for the specification of the setpoint position.
The position can be specified either as an absolute or a relative position.
0 =
Position Array
Position array - specification of absolute position
6
1 =
Pos. Inc. Array
Incremental position array - specification of relative position
6
2 =
Synchronous
Specification of position by master drive unit (note P509)
7
3 =
Bus
Specification
of
absolute
position via bus (note P509)
4 =
Bus Increment
Specification of relative position via bus, adoption with
synchronisation command
5 =
NOTE:
For further information, please refer to Sections 3.3.1 pr. 3.3.2 etc.
P611
P position control
S
0,1...100,0 %
[5 ]
The P amplification of the positioning control can be adjusted. Values which
are too large cause overshooting. Values which are too low cause imprecise
positioning. The rigidity of the axis when at a standstill increases with
increasing values of P.
P612
Pos. window
S
6
Any setpoint present from the bus (if 509, 546[01]…[02] are programmed accordingly) will be added!
7
Any programmed position increment via the digital inputs or bus IO In bits will be added!