4 Parameter settings


BU 0210 GB

Subject to technical amendments

33

Parameters
[factory setting]

Setting value / Description / Note

Device

Supervisor

Parameter
set

P434

Digital output function

P

0 ... 39

[ 7 ]

Control terminals 1/40:

The settings 3 to 5 and 11 work with a 10% hysteresis, i.e. the relay

contact closes (Function 11 opens) when the limit value is reached and opens (function 11
closes) when a 10% smaller value is undershot. This behaviour can be inverted with a negative
value in P435.

Setting / Function

Digital Output ...

for limit value or

function

(see also P435)

20:

Reference point

Closes

21:

Position reached

Closes

22:

Comparative position

Closes

23:

Comparative position value

Closes

24:

Position array value

Closes

25:

Comparative position reached

Closes

26:

Comparative position value reached

Closes

Caution:

The standardisation allocated to the output in parameter P435 is disabled for
functions relevant to PosiCon (20 – 26, see parameterisation of output function,
output 1, P434).

The hysteresis allocated to the output in parameter P436 is disabled for functions
relevant to PosiCon (20 – 26, see parameterisation of output function, output 1,
P434). With regard to the functions relevant to PosiCon, the joint parameterisation