4 Parameter settings
BU 0210 GB
Subject to technical amendments
33
Parameters
[factory setting]
Setting value / Description / Note
Device
Supervisor
Parameter
set
P434
Digital output function
P
0 ... 39
[ 7 ]
Control terminals 1/40:
The settings 3 to 5 and 11 work with a 10% hysteresis, i.e. the relay
contact closes (Function 11 opens) when the limit value is reached and opens (function 11
closes) when a 10% smaller value is undershot. This behaviour can be inverted with a negative
value in P435.
Setting / Function
Digital Output ...
for limit value or
function
(see also P435)
20:
Reference point
Closes
21:
Position reached
Closes
22:
Comparative position
Closes
23:
Comparative position value
Closes
24:
Position array value
Closes
25:
Comparative position reached
Closes
26:
Comparative position value reached
Closes
Caution:
The standardisation allocated to the output in parameter P435 is disabled for
functions relevant to PosiCon (20 – 26, see parameterisation of output function,
output 1, P434).
The hysteresis allocated to the output in parameter P436 is disabled for functions
relevant to PosiCon (20 – 26, see parameterisation of output function, output 1,
P434). With regard to the functions relevant to PosiCon, the joint parameterisation
of the hysteresis can be performed for all outputs via parameter P625.