4 Parameter settings


BU 0210 GB

Subject to technical amendments

35

Additional parameters:

Parameter
[factory setting]

Setting value / Description / Note

Device

Supervisor

Parameter
set

P502

[-01]

Master function value

S

P

0 ... 21

[ -01 = 0 ]

[ -02 = 0 ]

[ -03 = 0 ]

Selection of up to 3 master values:

[-01] =

Master value 1

[-02] =

Master value 2

[-03] =

Master value 3

Selection of possible master value settings relevant to PosiCon:

6 =

Actual position Low-word

7 =

Setpoint position Low-word

10 =

Actual position in incremental Low-word

11 =

Setpoint position in incremental Low-word

12 =

Bus IO Out Bits 0...7

13 =

Actual position High-word

14 =

Setpoint position High-word

15 =

Actual position in incremental

High-word

16 =

Setpoint position in incremental

High-word

P503

Master function output

0 ... 1

[ 0 ]

The output of the master function via the system bus is activated with this parameter.

The control words and setpoint values to be output refer to the P509 source of the FI control.
The master value to be transmitted via the system bus is determined in parameter P502.

Off System

bus

P514

CAN baud rate

0 ... 7

[ 4 ]

Setting of the transfer rate (transfer speed) via the system bus interface. All bus participants
must have the same baud rate setting.

0 =

10kBaud

1 =

20kBaud

2 =

50kBaud

3 =

100kBaud

4 =

125kBaud

5 =

250kBaud

6 =

500kBaud

7 =

1Mbaud *

*) Safe operation cannot be guaranteed

P515

[-01]

...

[-02]

CAN address (system bus)

0 ... 255

[ 50 ]

Setting of the system bus address.

P543

[- 01]

Actual bus value 1 3

S

P

0 ... 22

[ -01 = 1 ]

[ -02 = 4 ]

[ -03 = 9 ]

The return value can be selected for bus actuation in this parameter.

NOTE:

For further details please refer to the relevant Bus Manual BU 0250 or the

description for P418.

[-01] = Actual bus value 1

[-02] = Actual bus value 2

(only for PPO Type 2 or 4)

[-03] = Actual bus value 3

(only for PPO Type 2 or 4)

Possible values which can be set:

6 =

Actual position Low-word

7 =

Setpoint position Low-word

10 =

Actual position in incremental

Low-word

11 =

Setpoint position in incremental

Low-word

12 =

Bus IO Out Bits 0...7

13 =

Actual position High-word

14 =

Setpoint position High-word

15 =

Actual position in incremental High-word

16 =

Setpoint position in incremental High-word

22 =

Speed from rotary encoder (only possible with

rotary encoder feedback)