beautypg.com

3 door 2 door interlocks with a common door, Page 12 – Hoyles Interguard 2/3/4 door control unit with steel case & 5A PSU User Manual

Page 14

background image

J1

J1

LED5

LED5

LED6

LED6

LED4

LED4

LED3

LED3

LED2

LED2

LED1

LED1

J2

J2

IC

2
IC

2

021-650SE ISSUE 1

021-650SE ISSUE 1

L

A

B

E

L

L

A

B

E

L

C

O

N

T

R

O

L

C

O

N

T

R

O

L

P

R

O

D

U

C

T

IO

N

P

R

O

D

U

C

T

IO

N

HED

HED

C

C

B

B

A

A

DC POWER

DC POWER

DC POWER

DC POWER

R

E

L

A

Y

1

R

E

L

A

Y

1

R

E

L

A

Y

2

R

E

L

A

Y

2

R

E

L

A

Y

3

R

E

L

A

Y

3

R

E

L

A

Y

4

R

E

L

A

Y

4

RELAY 6

RELAY 6

RELAY 5

RELAY 5

R

E

M

O

T

E

I

N

D

IC

A

T

IO

N

S

R

E

M

O

T

E

I

N

D

IC

A

T

IO

N

S

1

2

+

V

E

1

2

+

V

E

F

I

N

P

U

T

S

F

I

N

P

U

T

S

R

I

N

P

U

T

S

R

I

N

P

U

T

S

D

I

N

P

U

T

S

D

I

N

P

U

T

S

C

C

D

D

S

S

X

X

--

--

--

--

+

+

+

+

+

+

+

+

GN4

GN4

GN3

GN3

GN2

GN2

GN1

GN1

RD4

RD4

RD3

RD3

RD2

RD2

RD1

RD1

+

+

+

+

+

+

+

+

F4

F4

F3

F3

F2

F2

F1

F1

D4

D4

R4

R4

D3

D3

R3

R3

D2

D2

R2

R2

R1

R1

D1

D1

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NO

NO

COM

COM

NC

NC

NC

NC

NO

NO

COM

COM

NC

NC

NO

NO

COM

COM

NC

NC

NO

NO

COM

COM

NO

NO

COM

COM

NC

NC

This setup allows for a common style of interlock, where 3 or 4 doors require interlocking as separate interlocks
with a common door. This would normally involve cross wiring between interlocks, but simply changing both
jumpers to position B allows an easy to connect 3 and 2 door combination interlock.

In the example, doors 1, 2 and 3 are interlocked, also door 3 is interlocked with door 4. However, doors 1 and 2
are not interlocked with door 4. All functions and indications are the same as the standard IG432. If the interlock
is breached, all 4 doors are considered as part of the problem. If there are only 3 doors in total, it is probably best
just to ignore door 1 and link D1 permanently to +ve to give the impression that the door is always closed. The
standard features; fire alarm, privacy and de-fog are all allowed in this mode. From a reliability point of view,
mode 1 operation is not permitted in this setup.

3 door 2 door interlocks with a common door

Page 12

Door 4

Door 3

Door 2

Door 1

Three door two door

interlock example

with door 3

common to both

interlocks