Hoyles DorWatcher door held open alarm User Manual
Dorwatcher, Dorwatcher installation, Hoyles electronic developments ltd
8mm (max).
Tamper loop
Magnet. Fit to door
and align with
door contact
Magnetic Door Contact. Fit
to door frame and
protect from moisture
Switch loop
Bk Bl Rd Yl
A1
A2
T1
T2
To1 To2
DorWatcher
Tamper
Input
Alarm
Input
DorWatcher Installation
Tamper Switch To1/To2
should be wired in series
with Rd/Blk tamper loop
from door contact to the
Tamper Input T1/T2 to
enable the box tamper.
DO NOT disconnect these
battery wires during installation
as incorrect re-connection may
cause damage to the unit.
DW304 only.
T
Fit the box tamper spring
to tamper switch labelled
T before closing the front
cover of the box.
F
U
S
E
N E L
220/240vac
DW306 only
16vac
from
transform
er
-ve
+ve
DW306 only
Battery Input
DW304 only
On
On
Off
Off
DELAY
CHIME
Jumper links shown in
factory default positions
Move jumpers to select the
required time delay TD1 and
TD2 (see over)
The DorWatcher is an alarm unit used to prevent doors being left open for an extended period of
time.
Ideal to help reduce costly false alarm call outs to the Fire Service caused by smoke from
cooking drifting out of kitchens in halls of residence and triggering fire alarm systems. Ensuring
external doors to buildings are not left open can also help reduce problems caused by vandals
entering communal areas of buildings such as flats or private members clubs.
When the protected door is opened the units LED will flash every few seconds and time delay
TD1 will elapse before a short warning chime is given by the unit. An additional time delay TD2
then elapses. If the door hasn't been closed after times TD1 and TD2 have elapsed, the unit will
give a full alarm tone. If the door is closed before the full alarm tone is heard, the unit will reset
and the next time the door is opened the timers will start again.
Once in full alarm, the tone will continue for 2 minutes after which time the alarm tone will cease
and a chime will be heard every 30 seconds to alert people in the vicinity that the door is still
open. To clear the alarm, close the door.
Overview
Normal Operation
Td1 and TD2 times are adjustable as follows:
Models available
DW304 - battery powered, DW305 - 12vdc powered, DW306 - 240vac mains powered
DorWatcher Inspection
We recommend that DorWatchers installed in locations prone to tampering/vandalism are fitted
with an anti-tamper screw (available separately) and inspected for signs of tampering on a
regular basis.
A simple visual check of the DorWatcher can be made:
Open the protected door, if the LED on the front panel flashes within 10 seconds then the
system is working correctly, if the LED does not flash and the alarm does not activate after the
preset time, contact your installation company for advice.
Battery fault indication
The battery powered DorWatcher model DW304 has a built in Battery fault monitor. If the unit
bleeps as soon as the door is opened, this indicates that the batteries are running low and
should be changed for new batteries (6 x AA).
TD1 (Seconds)
TD2 (Seconds)
Total Tim e to Alarm
Delay
Chim e
20
10
30 Seconds
Off
Off
40
20
1 Minute
On
Off
Factory Default
160
20
3 Minutes
Off
On
400
20
7 Minutes
On
On
Jum per Settings
Dwg No 60105 Oct13
COM
NO
NC
Volt free auxiliary
relay contacts
change on tamper
and main alarm
conditions DW305
& DW306 only
12 vdc power in 25ma DW305
12 vdc power out 150ma DW306
T. 01744 886600
F. 01744 886607
W. www.hoyles.com