Hoyles Stainless Steel EXITGUARD Flush mount User Manual

Start, Alarm, N e l

background image

www.hoyles.com

8mm (max gap).

Tamper

Tamper

Magnet. Fit to door
& align with contact

Magnetic Door Contact.
Fit to door frame and
protect from moisture

Contact

Bk Rd Yl Bl

Dwg 60095 Iss 3 Oct 13

Lo

Lo

On

On

On

On

On

On

On

On

On

On

Hi

Hi

Off

Off

Off

Off

Off

Off

Off

Off

Off

Off

TONE

TONE

DELAY

DELAY

DELAY

DELAY

DELAY

CHIME

CHIME

CHIME

CHIME

CHIME

Key Reset
ie 2mins +

90s

10s

1s

Jumper links shown in
factory default positions

Move jumper to select

low pitch tone

Move jumper to select 15s

alarm delay (DOTL)

Move jumper to select

door chime facility

COM

NO

NC

A1

A2

T1

T2

-ve

+ve

K1 K2 To1To2

Volt free auxiliary relay
contacts.
Change on alarm condition
EX105 & Ex106 versions

6 x AA batteries
(Ex104 versions)
Do NOT power
from 12vdc.
This will result
in damage.

Keys

witch

12 vdc Power In Ex105
or
12 vdc Power Out 150ma EX106

EXITGUARD EX104, EX105 & EX106

24 hour Door Alarm

Tamper
Input

Alarm
Input

Start

Key

90s

10s

1s

Alarm

Chime

or

Alarm

Chime [1]

Auto

or Key

Reset

Delayed

or Instant

Alarm

Warning

at start of

delay

Auto reset

Delayed

Instant [4]

Yes

No

Basic CHIME facilty repeats at 15second intervals

Auto Reset time can be adjusted between 1 sec
and 90 secs. Beyond 90 secs it becomes Key Reset

Turn pot fully
clockwise to
invoke Key Reset
ie Factory default

Set jumpers for desired operation

Note: There are no programming
options for tamper facilities.

Control with

Keyswitch

Factory

Default

Options

The EX100 series EXITGUARD provides a simple to operate solution for the 24 hour protection of fire exit and
other doors. A number of options are available that can be set up at the installation stage. The following
features are standard to all EX100 series EXITGUARDs:

4Basic Chime repeating at 15 sec intervals [1]

4Auto Reset adjustable 1 sec to 90 secs [2]

4Keyswitch Reset [3]

4Instant Alarm [4]

4Reduced alarm after 2 minutes if not reset

4Delay before alarm without pre-warn [5]

4Delay before alarm with pre-warn [6]

4Low level tamper for 2 mins then every 5 mins

4Tamper omit.

4Low battery warning on set & at 5 min intervals

4Hi & Lo level alarm tones

4LED status indicator

4Double bleep for set, single bleep for un-set.

4Pass through/ safe set facility.

Powered from 6 x AA batteries (supplied) EX104 or from a
12vdc intruder alarm supply Ex105

[1]

[5]

[6]

[2]

[3]

RESET
CONTROL

The exact position for maximum reset time
(90 secs) is approx. 2 o'clock. To determine
this position exactly ensure that the door
contact and the tamper loop are both open.
The keyswitch should be in the O (Off)
position. Apply power and switch to the I
(On) position within 3 seconds. The sounder
will give a bleep followed by four rapid bleeps
Turn the potentiometer slowly and observe
the following:
At Key Reset a Chime & no LED
At Max Reset a Barp & no Led
Below Max Reset Silence and steady LED

Tone Select does
not affect any other
programming

16vac

from

transformer

F
U
S
E

N E L

220/240vac
EX106 only

NC

COM

NO

Blue

Yellow

White

EX105KM is fitted
with auxiliary volt
free terminals for
remote signalling
of Set/Unset