Hoyles Stainless Steel EXITGUARD Flush mount User Manual
Start, Alarm, N e l
www.hoyles.com
8mm (max gap).
Tamper
Tamper
Magnet. Fit to door
& align with contact
Magnetic Door Contact.
Fit to door frame and
protect from moisture
Contact
Bk Rd Yl Bl
Dwg 60095 Iss 3 Oct 13
Lo
Lo
On
On
On
On
On
On
On
On
On
On
Hi
Hi
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
TONE
TONE
DELAY
DELAY
DELAY
DELAY
DELAY
CHIME
CHIME
CHIME
CHIME
CHIME
Key Reset
ie 2mins +
90s
10s
1s
Jumper links shown in
factory default positions
Move jumper to select
low pitch tone
Move jumper to select 15s
alarm delay (DOTL)
Move jumper to select
door chime facility
COM
NO
NC
A1
A2
T1
T2
-ve
+ve
K1 K2 To1To2
Volt free auxiliary relay
contacts.
Change on alarm condition
EX105 & Ex106 versions
6 x AA batteries
(Ex104 versions)
Do NOT power
from 12vdc.
This will result
in damage.
Keys
witch
12 vdc Power In Ex105
or
12 vdc Power Out 150ma EX106
EXITGUARD EX104, EX105 & EX106
24 hour Door Alarm
Tamper
Input
Alarm
Input
Start
Key
90s
10s
1s
Alarm
Chime
or
Alarm
Chime [1]
Auto
or Key
Reset
Delayed
or Instant
Alarm
Warning
at start of
delay
Auto reset
Delayed
Instant [4]
Yes
No
Basic CHIME facilty repeats at 15second intervals
Auto Reset time can be adjusted between 1 sec
and 90 secs. Beyond 90 secs it becomes Key Reset
Turn pot fully
clockwise to
invoke Key Reset
ie Factory default
Set jumpers for desired operation
Note: There are no programming
options for tamper facilities.
Control with
Keyswitch
Factory
Default
Options
The EX100 series EXITGUARD provides a simple to operate solution for the 24 hour protection of fire exit and
other doors. A number of options are available that can be set up at the installation stage. The following
features are standard to all EX100 series EXITGUARDs:
4Basic Chime repeating at 15 sec intervals [1]
4Auto Reset adjustable 1 sec to 90 secs [2]
4Keyswitch Reset [3]
4Instant Alarm [4]
4Reduced alarm after 2 minutes if not reset
4Delay before alarm without pre-warn [5]
4Delay before alarm with pre-warn [6]
4Low level tamper for 2 mins then every 5 mins
4Tamper omit.
4Low battery warning on set & at 5 min intervals
4Hi & Lo level alarm tones
4LED status indicator
4Double bleep for set, single bleep for un-set.
4Pass through/ safe set facility.
Powered from 6 x AA batteries (supplied) EX104 or from a
12vdc intruder alarm supply Ex105
[1]
[5]
[6]
[2]
[3]
RESET
CONTROL
The exact position for maximum reset time
(90 secs) is approx. 2 o'clock. To determine
this position exactly ensure that the door
contact and the tamper loop are both open.
The keyswitch should be in the O (Off)
position. Apply power and switch to the I
(On) position within 3 seconds. The sounder
will give a bleep followed by four rapid bleeps
Turn the potentiometer slowly and observe
the following:
At Key Reset a Chime & no LED
At Max Reset a Barp & no Led
Below Max Reset Silence and steady LED
Tone Select does
not affect any other
programming
16vac
from
transformer
F
U
S
E
N E L
220/240vac
EX106 only
NC
COM
NO
Blue
Yellow
White
EX105KM is fitted
with auxiliary volt
free terminals for
remote signalling
of Set/Unset