This call point (S1663P) is designed for use with the
MULTIGUARD 2000 patient nurse call system (MG311000 and
MG311100). In addition to being able to generate a call by
pressing the large red button on the facia it is also possible to
reset any calls by simultaneously pressing the blue button and
the central green button/LED. An emergency recall can also be
generated at any time by simultaneously pressing the yellow
button and the central green button/LED.
The call point has an integral electronic timer which is started
whenever a call is generated. If the call has not been reset within
a predetermined period then a late attendance signal is sent to
the control equipment to re-alert staff at the nurse station. The
integral timer is adjustable over the range 30 seconds to about 2
minutes and will continue to send the signal at the periodic
intervals until the call point has been reset.
Facilities are provided for the connection of auxiliary devices
such as:-
A. an external ceiling mounted Pull-Cord with re-assurance
LED S/1600.
B. a hand held pillow push. S/1631 or other open circuit device
C. an overdoor light unit. S/1636
Details of these devices and their connection to the call point can be found overleaf.
Note: The MG311XXX controllers is a non-latching device. A pull cord, pillow push or other non-
latching call devices cannot be connected directly to the MULTIGUARD MG311XXX controllers
without an S/1663 call point. The call point provides an electronic latching circuit.
1 2 3 4 5 6 + + 1 2 3 4 + -
INPUTS
FUNCTION
INPUTS
Link F2 to +ve to disable silence function
S/1663
Complies with Council
Directive 89/336/EEC
+ve
-ve
E/Recall
L/Attend
CALL OUT
Call In
+ve
Reset In
-ve
+ve
LED
Late Attend
Timer
S/1663
Call Point
+ve
-ve
E/Recall
L/Attend
CALL OUT
Call In
+ve
Reset In
-ve
+ve
LED
Late Attend
Timer
S/1663
Call Point
+ve
-ve
E/Recall
L/Attend
CALL OUT
Call In
+ve
Reset In
-ve
+ve
LED
Late Attend
Timer
S/1663
Call Point
+ve
-ve
E/Recall
L/Attend
CALL OUT
Call In
+ve
Reset In
-ve
+ve
LED
Late Attend
Timer
S/1663
Call Point
Pillow push or Pull Cord
Input. Normally Open, Close
to Call
Output for Re-assurance LED
on Pull Cord or Overdoor Light
See overleaf for connection
details
MG311000
& MG311100
+ve
-ve
E/Recall
L/Attend
CALL OUT
Call In
+ve
Reset In
-ve
+ve
LED
Late Attend
Timer
S/1663
Call Point
CALL
RESET RE-CALL
MULTIGUARD CALL/RESET
POINT S1663P
The call point is
designed to fit into
a standard single
gang pattress box
or flush mount
accessory box.
A box of 25mm or
greater depth is
recommended.
Eg. S/1680 or
TE55
A 10 core cable can be used for
each six zones. It is possible to
connect a number of call points
into one zone of the annunciator
To additional
call points
To additional
call points
T. 01744 886600 E. [email protected]
F. 01744 886607 W. www.hoyles.com
Hoyles Electronic Developments Ltd