Door 1 door 2, Page 8, Mode 3 function link mode 3 function link – Hoyles Interguard 2/3/4 door control unit with steel case & 5A PSU User Manual

Page 10: S1718s, F1 fire alarm function f2 fire alarm function, S1726s privacy button if required

background image

Mode 3 operation with door openers and request to release

J1

J1

LED5

LED5

LED6

LED6

LED4

LED4

LED3

LED3

LED2

LED2

LED1

LED1

J2

J2

IC

2
IC

2

021-650SE ISSUE 1

021-650SE ISSUE 1

L

A

B

E

L

L

A

B

E

L

C

O

N

T

R

O

L

C

O

N

T

R

O

L

P

R

O

D

U

C

T

IO

N

P

R

O

D

U

C

T

IO

N

HED

HED

C

C

B

B

A

A

DC POWER

DC POWER

DC POWER

DC POWER

R

E

L

A

Y

1

R

E

L

A

Y

1

R

E

L

A

Y

2

R

E

L

A

Y

2

R

E

L

A

Y

3

R

E

L

A

Y

3

R

E

L

A

Y

4

R

E

L

A

Y

4

RELAY 6

RELAY 6

RELAY 5

RELAY 5

R

E

M

O

T

E

I

N

D

IC

A

T

IO

N

S

R

E

M

O

T

E

I

N

D

IC

A

T

IO

N

S

1

2

+

V

E

1

2

+

V

E

F

I

N

P

U

T

S

F

I

N

P

U

T

S

R

I

N

P

U

T

S

R

I

N

P

U

T

S

D

I

N

P

U

T

S

D

I

N

P

U

T

S

C

C

D

D

S

S

X

X

--

--

--

--

+

+

+

+

+

+

+

+

GN4

GN4

GN3

GN3

GN2

GN2

GN1

GN1

RD4

RD4

RD3

RD3

RD2

RD2

RD1

RD1

+

+

+

+

+

+

+

+

F4

F4

F3

F3

F2

F2

F1

F1

D4

D4

R4

R4

D3

D3

R3

R3

D2

D2

R2

R2

R1

R1

D1

D1

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NC

NC

COM

COM

NO

NO

NO

NO

COM

COM

NC

NC

NC

NC

NO

NO

COM

COM

NC

NC

NO

NO

COM

COM

NC

NC

NO

NO

COM

COM

NO

NO

COM

COM

NC

NC

+

-

S1718S

S1718S

S1718S

S1717S

DOOR 1

DOOR 2

Door Operator

Door Operator

BREACH

INDICATOR

8581750/HB

S1788PY

link unused

door contacts

to +ve

F1 Fire Alarm Function

F2 Fire Alarm Function

interguard

interguard

interguard

interguard

press to release

press to release

press to release

COM
N/O

Alternative RTR

Card reader etc

momentary action

clean contact

Page 8

Operational Note.
The lock relay switches when a request is accepted and then remains switched for the entire dwell
time. If the door is opened the relay will follow the request input after the dwell time has expired.

Door Operators.
The door operator requires a momentary closed input to open the door and then automatically closes it. The
door operator may have a door status output. If not, a door contact must be used.

mode 3

function

link

mode 3

function

link

S1726S

Privacy button

if required

interguard

Press to Lock

Door Control

Press again to Unlock