FUTEK IPM52x (D520) Digital Display User Manual
Page 28

27
•
Pushing
F key will display the assigned peak function. If
peak was assigned peak LED on front panel will also
light. If Valley then valley LED will light.
•
Pushing
F key for 4 seconds will reset the peak/valley.
2.
"r in 1", and "r in 2” remote inputs. RUN mode remote/external input
setup
The 2 Remote input functions are selected under the Main program
branch heading "SPEC". A TTL level applied to the input enables
the following.
!
"RESET"
- Resets latched relays
!
"TARE"
- Zeros display for channel being displayed.
! "HOLD" - Freezes display and suspends measurements
! "SCALE2" - Selects second scaling to be applied to channel
being displayed. S2 light on front panel is lit.
!
"LOCK"
- Locks out access to the SETUP programs
! "PEAK 1" - Display PEAK 1
! "PEAK 2" - Display PEAK 2
!
"ALARM" - Disables alarms. Meter functions normally but no
alarms are activated when they go beyond their preset limits.
!
"DEC PT"
- Selects the decimal point programmed
! "CHAN" - Selects the channel programmed
!
"PRESET"
- Resets both peak and valleys.
!
"NET/GROSS"
- Displays Gross value of channel
!
“PRINT” – Initiates a print of the current display through the
RS-232C serial port. (T option required for this function.)
3.
20 point linearization
Allows the user to program and assign a 19-segment linearization
program to one channel.
"On"/"OFF" - On enables the linearization table, off disable the
linearization table
"CHAN 1"
"CHAN 2 " Assigns the linearization to a channel
"CHAN 3"
"SEGS"
- Total number of segments (1-19)
"In 1” through "In 19"
- Enter the 19 input values
"OUT 1" through "OUT 19"
- Enter the 19 output values