and “NO” for non-latching. Use the
ENTER key to enter choice.
Note: “
RESET” function programmable for front panel key or
remote input, is used to reset the latched alarm.
h.
"SAFE" ("ALARM 1" ONLY) selects alarms 1 through 3 to be
in a safe mode (de-energizes on alarm) or standard (energizes on
alarm). Use
SELECT key to view “YES” for safe and “NO” for
standard. Use the
ENTER key to enter choice. Note: This is
used to determine what the alarms do when loss of power occurs
to meter. With "SAFE" selected alarm will turn on when power
fails.
i.
"FLASH" selects alarm to flash display when in alarm. Use
SELECT key to view “YES” for flash display and “NO” don’t
flash display. Use the
ENTER key to enter choice.
j.
“ENABLE” selects if set point is changeable in the run mode, or
just viewing a load.
2.
ANALOG OUTPUT
This setup menu programs the analog output/retransmission.
a.
"SOURCE" selects what the analog output will be based upon.
Use
SELECT key to view choices. Use ENTER key to enter
choice. After choice is entered then addition choices are entered.
1.
Selections are:
•
"CHAN 1"
Channel 1
a)
"GROSS"
gross value (default)
b)
"NET"
net value
c)
"PEAK 1"
peak 1 value
•
"CHAN 2"
Channel 2
a)
"GROSS"
gross value
b)
"NET"
net value
c)
"PEAK 1"
peak 1 value
•
"CHAN 3"
Channel 3
a)
"GROSS"
gross value
b)
"NET"
net value
c)
"PEAK 1"
peak 1 value
•
"DISPLY"
What ever is currently
selected