beautypg.com

FUTEK IPM52x (D520) Digital Display User Manual

Page 26

background image

25

"F1 SET" thru "F4 SET" programs the RUN mode function of

the 4

F keys

"r in 1" thru "r in 2" programs the function of the 2 remote inputs

"20 Pt" programs the 20 point linearization table and assigns it to

one channel

"PEAK 1" programs the peak or valley function of each channel

"PEAK 2" programs second the peak or valley function of each

channel

"SCALE2" programs the second scaling parameters of each

channel

"CODE" programs the lockout code for authorized entry into

SETUP

"DEFAUL" sets meter setup back to default setup

1.

"F1 SET", "F2 SET", "F3 SET" and "F4 SET" - RUN MODE function

key setup

This programs the function of the 4 front panel

F keys.

A.

"ALAR 1" thru "ALAR 4” assigns alarm function to F keys

Pushing F key displays current alarm set point

Pushing F key for 4 seconds allows point value to be

changed.

Current set point is displayed with the right most digit

flashing. The set point can now be changed with the

UP and DOWN keys. Select digit to be changed with

SELECT key. Press ENTER key to enter new value

into memory and return to RUN mode

B.

"TARE 1", "TARE 2" and "TARE 3" assigns

F key for tare

function. 1 for channel 1, 2 is for channel 2 and 3 for math

channel 3.

Pushing

F key will zero the Channel for the input

present.

Pushing

F key for 4 seconds will reset the tare value to

zero.

"CHAN 1" assigns F key to display Channel 1

"CHAN 2" assigns F key to display Channel 2

"CHAN 3" assigns F key to display Channel 3