Particulate Monitoring Systems
Installation & Operating Manual
Document No. 210-1003-M
Page 40
©2007
2:11
Thru
2:15
- 0
1
Bool
Not
Used
3
40609
Particulate process variable LO word
4 40610
0 5000
pA
Float
Particulate process variable HI word
5
40611
Averaged particulate process variable LO word
6 40612
0 5000
pA
Float
Averaged particulate process variable HI word
7
40737
Alarm level – Max alarm #1 LO word
8 40738
0 5000
pA
Float
Alarm level – Max alarm #1 HI word
9
40739
Alarm level – Pre-visible alarm #2 LO word
10 40740
0 5000
pA
Float
Alarm level – Pre-visible alarm #2 HI word
11
40769
0
600
Usint
Alarm delay – Max alarm #1
12
40770
0
600
Usint
Alarm delay – Pre-visible alarm #2
Output (O->T) Assembly Object (Class 0x04, Instance 0x66)
The following is a mapping of I/O values for the standard Ethernet/IP® assembly object instance
0x66. These are values that are sent from the Ethernet/IP® client (typically a PLC) to the
Ethernet/IP® server (control unit). The first word in the map contains the run/idle bit (bit 0). The
run/idle bit controls write access to the control unit. When the run/idle bit is set to 0 the control
unit is set to idle mode. In idle mode, the Ethernet/IP® server will allow read only access to the
control unit. When the run/idle bit is set to 1 the control unit is set to run mode. In run mode, the
Ethernet/IP® server will allow both read and write access to the control unit. The run/idle control
is defined for communications purposes only and has no affect on any other normal
control/sensing/alarming operation of the control unit. The output assembly size is 7 (16 bit
words).
Data Types
Bool – 1 bit Boolean discrete data
Usint – 16 bit unsigned integer analog data
Sint – 16 bit signed analog data
Float – 32 bit signed floating point analog data
Floating point values are represented in IEEE format (32-bit) where the 1
st
register is the LOW
word and the 2
nd
register is the HIGH word.
Output (O->T) Assembly Object (Class 0x04, Instance 0x66) Size 7 (16 bit words)
16-Bit
Word
Modbus
®
Range Range Units
Data
Type
Description
Address Address Min Max
0
-
0
1
Usint
Run/Idle mode setting (0=idle/read only, 1=run/read write)
1
40737
Alarm level – Max alarm #1 LO word
2 40738
0 5000 pA Float
Alarm level – Max alarm #1 HI word
3
40739
Alarm level – Pre-visible alarm #2 LO word
4 40740
0 5000 pA Float
Alarm level – Pre-visible alarm #2 HI word
5 40769 0 600 Sec Usint
Alarm
Delay
HI
Particulate
6
40770
0
600
Sec
Usint
Alarm Delay HI Delta P