Particulate Monitoring Systems
Installation & Operating Manual
Document No. 210-1003-M
Page 9
©2007
4.3 Sensor Temperature Considerations
The sensor may be ordered with one of three process temperature ranges:
1. -40ºF to 250ºF (-40ºC to 121ºC)
2. -40ºF to 450ºF (-40ºC to 232ºC)
3. -40ºF to 800ºF (-40ºC to 426ºC)
4. Consult Factory for Temperatures >800°F
Note: For the process temperatures in the range of 233ºC - 426ºC, a high temp probe must be used.
The maximum allowable ambient temperature at sensor housing is 70ºC.
Table: T Code Rating for Sensor
Process Temperature Does Not Exceed
Maximum Ambient
75ºC (167ºF)
125ºC (257ºF)
225ºC (437ºF)
325ºC (617ºF)
426ºC (800ºF)
70ºC (160ºF)
T6
T4
T2C
T1*
T1*