Easicool™ precision air conditioning, Te ch nic al x-t yp e df, Technical data downflow units x type – Airedale EasiCool 6kW 64kW User Manual
Page 63: Electrical data, Df6x - df10x
EasiCool™
Precision Air Conditioning
63
EasiCool Technical Manual 7525389 V1.1.0_02_2013
Te
ch
nic
al
X-T
yp
e
DF
Mechanical
(1)
Entering air 24°C/45% RH ambient 35°C.
(2)
Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3)
With Standard forward curved fan motors; Machine weight includes a refrigerant charge.
(4)
Backward curved EC fan options quote electrical power. All other options quote shaft power.
(5)
For refrigerant charges, refer to
Unit Refrigerant Charge (kg/Circuit)
.
(6)
Based on air temperature of 15.5°C leaving the evaporator coil.
(7)
Based upon low pressure hot water 82°C inlet / 71°C outlet. Air on 20°C. Refer to
Low Pressure Hot Water
.
Electrical
(1)
Values given for full function units (incl. electric heating, humidification and matched condenser) at 7°C evaporating and 54.4°C condensing with standard
forward curved fan motors, for optional data, please contact Airedale.
(2)
Values given for Cooling only units (incl. Compressor, evaporator fan and matched condenser) at 7°C evaporating and 54.4°C condensing, for optional
data, please contact Airedale.
(3)
Electrical input power relates to the maximum absorbed electrical power. Actual operating fan power input is shown in the mechanical data tables.
Technical Data Downflow Units X Type
Electrical Data
DF6X-EZRE-0
DF8X-EZRE-0
DF10X-EZRE-0
Standard Condenser Match
1 x CR12
1 x CR16
1 x CR16
Max Mains Incoming Cable Size
mm²
6
6
6
Mains Supply
V
400V / 3PH + N / 50HZ
Control Circuit
VAC
24
24
24
Unit Data Full Function - X
(1)
Nominal Run Amps
A
20.0
21.0
21.2
Maximum Start Amps
A
42.4
51.4
58.6
Recommended Mains Fuse Size
A
25
25
25
Unit Data Cooling Only - X
Nominal Run Amps
(2)
A
9.2
10.2
10.4
Maximum Start Amps
A
31.6
40.6
47.8
Recommended Mains Fuse Size
A
16
16
16
Evaporator Fan - EC Motor Per Fan
Centrifugal Forward Curved DD EC - Designed to 25Pa ESP
Quantity
1
1
1
Maximum Electrical Input Power
(3)
kW
1.3
1.3
1.15
Full Load Amps
A
5.6
5.6
4.8
Locked Rotor Amps
A
5.6
5.6
4.8
Compressor - Per Compressor
Quantity x Motor Size
kW
1 x 2
1 x 2.6
1 x 3.3
Nominal Run Amps
A
3.6
4.6
5.6
Locked Rotor Amps
A
26
35
43
Type of Start
Direct On Line
Standard Condenser Match - AC Motor - Per Fan
Quantity
1
1
1
Maximum Electrical Input Power
kW
0.27
0.27
0.27
Full Load Amps
A
1.1
1.1
1.1
OPTIONAL EXTRAS
Electric Heating
Stage of Reheat
1
1
1
Number of Elements
3
3
3
Rating
kW
7.5
7.5
7.5
Current per Phase
A
10.83
10.83
10.83
Humidifier
Capacity
kg/hr
3
3
3
Rating
kW
2.25
2.25
2.25
Full Load Amps
A
3.25
3.25
3.25
Evaporator Fan Options
Larger Fan Motor - AC Motor - Per Fan
Quantity
Maximum Electrical Input Power
(3)
kW
N/A
N/A
N/A
Full Load Amps
A
N/A
N/A
N/A
Locked Rotor Amps
A
N/A
N/A
N/A
Standard Size Motor - EC Motor - Per Fan
Centrifugal Backward Curved DD EC - Designed to 25Pa ESP
Quantity
1
1
1
Maximum Electrical Input Power
(3)
kW
0.94
0.94
0.94
Full Load Amps
A
1.5
1.5
1.5
Condenser Fan Options
Standard Condenser Motor - EC Motor - Per Fan
Quantity
1
1
1
Maximum Electrical Input Power
(3)
kW
0.7
0.7
0.7
Full Load Amps
A
3.1
3.1
3.1
DF6X - DF10X