beautypg.com

Sample profile – West Control Solutions MRC 7000 Profiler Manual User Manual

Page 83

background image

83

SAMPLE PROFILE

The following is a sample profile intended to assist in understanding how the profile recorder
functions. Be sure to disconnect all control outputs before running this profile. This profile
does not make use of the second pen on a dual pen instrument to help keep the profile short.

Press and release the SCROLL key until Prog appears on the display then press the DOWN
key. Press and release the DOWN key until diSp appears then press the SCROLL key. Press
and hold the UP key until the display shows a 5 then press the SCROLL key. Press and
release the Down key until Ptb appears then press the SCROLL key. Press and hold the UP
key until a 3 appears then press the SCROLL key. Press the UP key and Prog will appear.
Press and release the SCROLL key until PEnt appears then press the DOWN key. Perform
the following keystrokes:
Display

Keystroke

Pn

SCROLL

X

DOWN

1

SCROLL

nS

SCROLL

X

UP

6

SCROLL

rt

SCROLL

X

UP/DOWN

0.10

SCROLL

SP

SCROLL

X

UP/Down

100

SCROLL

St

SCROLL

X

UP/DOWN

0.10

SCROLL

rt

SCROLL

X

UP/DOWN

0.10

SCROLL

SP

SCROLL

X

UP/DOWN

150

SCROLL

St

SCROLL

X

UP/DOWN

rt

SCROLL

X

UP/DOWN

0.10

SCROLL

SP

SCROLL

X

UP/DOWN

300

SCROLL

St

SCROLL

X

UP/DOWN

0.10

SCROLL

rt

SCROLL

X

UP/DOWN

0.10

SCROLL

SP

SCROLL

X

UP/DOWN

200

SCROLL

St

SCROLL

X

UP/DOWN

0.10

SCROLL

rt

SCROLL

X

UP/DOWN

0.10

SCROLL

SP

SCROLL

X

UP/DOWN

100

SCROLL

St

SCROLL

X

UP/DOWN

0.10

SCROLL

rt

SCROLL

X

UPDOWN

0.10

SCROLL

SP

SCROLL

X

UP/DOWN

50

SCROLL

St

SCROLL

X

UP/DOWN

0.10

SCROLL

PLct

SCROLL

X

UP/DOWN

2

SCROLL

dHru

SCROLL

X

UP/DOWN

0

SCROLL

dHrd

SCROLL

X

UP/DOWN

0

SCROLL

PEnt

SCROLL

X

UP/DOWN

0

SCROLL

Pn

UP

PEnt

With PEnt on the display,
press and release the
SCROLL key until P 1
appears in the display then
press RUN/ HOLD key. The
display will show run, then
display the ramping setpoint
of the profile. This is to
demonstrate how the profile
recorder controller functions.