West Control Solutions MRC 7000 Profiler Manual User Manual
Page 34

34
53
Pen(s) Profile/ (Control)
PPC
1 or 2
1
Profiles/(Profile)
1=Pen 1 profiles & controls
Configuration
process.
(only seen on 2 pen instr.)
Pen 2 (if present) records
& controls process.
2=Pen 1 profiles & controls
process.
Note: Time base between
both pens are shared.
54
Chart Rotation Time
Crt
0.1 to 999.9 hours per
1.0
rotation
55
Pen Action on Power Up
PAPu
0=Pen(s) go to the "home"
0
posistion (toward chart
cetner) when powered up
1=Pen(s) remain in last
position prior to power down
56
Chart Operation
Coo
0 to 1
0
in Off Mode
0=Chart continues rotating
in the Off mode
1=Chart stops rotating while
in the Off mode
COMMUNICATIONS OPTIONS PARAMETERS
57
Communication
CCon
0 to 4
3
Configuration
0=Off
1=Monitor Mode (Read Only)
2=Normal Mode (Read and Write)
3=Total Access with Limit Checking
4=Total Access without Limit Checking
58
Communication Bit
CbS
1 to 6
6
Rate Selection
1=300
Will not be seen if
2=600
Con=0
3=1200
4=2400
5=4800
6=9600
59
Communications
CAd1
0 to 99
1
Address-Pen 1
Will not be seen if
Con=0
60
Communications
CAd2
0 to 99
2
Address-Pen 2
(If provided)
Will not be seen if
Con=0
DISPLAY AVAILABLE
FACTORY YOUR
STEP
DESCRIPTION
CODES SETTINGS
SETTING SETTING