Installation and operating instructions

35

BATCHFLUX


5.13 F/R mode, forward / reverse flow measurement

Refer to Sect. 2.3 for electrical
connection of the outputs.

Define direction of forward (normal)
flow,
see Fct. 3.2, subfunction “FLOW
DIR.“:

in conjunction with F/R operation, set the
direction for the forward flow here.

“+“ signifies the same direction as shown
by the arrow on the primary head, “-“
signifies the opposite direction.

Set the status indication output to
“F/R INDIC.“, see Fct. 1.7.

Set the current and / or pulse output to
“2 DIR.“, see Fct. 1.5 and 1.6, subfunctions
“FUNCTION I“ and “FUNCTION P“.