beautypg.com

KROHNE BATCHFLUX 5015 K EN User Manual

Page 29

background image

Installation and operating instructions

29

BATCHFLUX



5.4 Display with HHT 010


Fct. 1.4 DISPLAY
Press key

.

DISP.FLOW = Select unit for display
of flowrate,
press key

NO DISP. (not

displayed)

m

3

/hr

(cubic metres per hour)

Liter/Sec

(litres per second)

US.Gal/min

(US gallons per minute)

User-defined unit; factory-set is

„Liter/hr“ (litres per

hour), see Sect. 5.12

PERCENT (percentage

display)

BARGRAPH

(numerical value and

bar graph display in %)


Select with keys

and ↓.

Press key

to transfer to subfunction

“DISP.COUNT“

DISP.COUNT = Select unit for totalizer
display,
press key

NO DISP.

(not displayed)

OFF

(internal totalizer

switched off)

m

3

(cubic metres)

Liter

(litres)

US.Gal

(US gallons)

user-defined unit; factory-set is “Liter“,

see Sect. 5.12


Select with keys

and .

Transfer to totalizer format setting with key

.


Setting of totalizer format
Auto (exponent notation)

# . #######

##### . ###

## . ######

###### . ##

### . #####

####### . #

#### . ####

########


Select with keys

and .

Transfer to subfunction “DISP.MSG.“ with
key

.

DISP.MSG. = Additional messages
required in measuring mode,
press key

NO

(no other messages)

YES

(display other messages,

e.g. errors, in sequence with the

measured

values)


Select with keys

and .

Press key

to return to Fct. 1.4 DISPLAY.

Note: “BUSY“ is displayed in the measuring
mode when all displays are set to “NO DISP.“
and
“NO“. Sequencing of displays is automatic.
However, in the measuring mode, manual
sequencing can be carried out with keys

and

↓ . Return to automatic sequencing after

approx. 3 minutes.
Please refer to Sect. 3.2
“Factory settings“.


5.5 Internal electronic totalizer


The internal electronic totalizer counts in m

3

,

regardless of the unit set under Fct. 1.4,
subfunction “DISP.FLOW“.
The counting range is dependent upon the
meter size and has been selected such that
the totalizer will count for a minimum of 1 year
without overflow:

Meter size

Counting range

DN mm inches

in m

3

2,5 - 40

1

/

10

- 1

1

/

2

0 - 999 999.99999999



Only part of the totalizer count is shown in the
display because it is not possible to output a
14-digit number. Unit and format of the display
are freely selectable, see Fct. 1.4, subfunction
“DISP.COUNT“ and Sect. 5.4. This determines
which part of the count is to be displayed.
Display overflow and totalizer overflow are
independent of one another.

Example

Internal count

0000123 . 7654321 m

3

Format,
display unit

XXXX . XXXX

Liter

Internal count
in unit

0123765 . 4321000 Liter

Displayed

3765 . 4321

Liter

5