Section 5.6

Part C Technical data, Block diagram and Measuring principle

ALTOFLUX 2W

02/2001

40

5.6

Limits

PLEASE NOTE !

The limits specified in the table for process
temperature and operating pressure make
allowance for the tube liner and the flange
standard.

Abbreviation used:

DIN

= DIN 2501 (= BS 4504)

ANSI = ANSI B 16.5

Refer to certificates of conformity for max.
allowable operating data for hazardous-duty
versions, provided only with hazardous-duty
equipment.

Limits for Teflon

®

PFA liner und Teflon

®

PTFE liner

Liner Flanges

Max. operating pressure in bar (psig) at a process temperature of ...

Standard

Nominal
diameter

Pressure
rating /
Class

40 °C

(≤

105 °F)

60°C

(≤

140 °F)

70 °C

(

158 °F)

90 °C

(≤

195 °F)

100 °C

(≤

210 °F)

120 °C

(≤

250 °F)

140 °C

(≤

284 °F)

1)

PFA

DIN

DN 25, 50, 80

PN 40

40

(580) 40

(580) 40

(580) 40

(580) 40

(580) 40

(580) 40

(580)

DN 100, DN 150 PN 16

16

(232) 16

(232) 16

(232) 16

(232) 16

(232) 16

(232) 16

(232)

ANSI

1“, 2“, 3“, 4“, 6“

150 lb

19.6 (284) 19.0 (275) 18.7 (271) 18.1 (262) 17.7 (256) 17.0 (246) 16.2 (235)

300 lb

on request

PTFE DIN

DN 10, DN 15

PN 40

40

(580) 40

(580) 40

(580) 40

(580) 40

(580) 40

(580) 40

(580)

ANSI

3

/

8

“,

1

/

2

"

150 lb

19.6 (284) 19.0 (275) 18.7 (271) 18.1 (262) 17.7 (256) 17.0 (246) 16.2 (235)

300 lb

on request

1)

ambient temperature with max. +40 °C / +104 °F

Vacuum load

Liner Nominal diameter

Max. operating pressure in mbar (psia) at a process temperature of ...

DIN

ANSI

40 °C

(≤

105 °F)

60 °C

(≤

140 °F)

70 °C

(

158 °F)

90 °C

(≤

195 °F)

100 °C

(≤

210 °F)

120 °C

(≤

250 °F)

140 °C

(≤

284 °F)

PFA DN 25 - 150

1“- 6“

0

(0)

0

(0)

0

(0)

0

(0)

0

(0)

0

(0)

0

(0)

PTFE DN 10, DN 15

3

/

8

“,

1

/

2

0

(0)

0

(0)

0

(0)

0

(0)

0

(0)

500

(7.3)

750

(9.7)

Teflon

®

is a registered trademark of Du Pont.