beautypg.com

Technical data, 4 antenna selection – KROHNE BM 702 A EN User Manual

Page 54

background image

8

TECHNICAL DATA

54

BM 702 A

www.krohne.com

09/2009 - 4000643301 - MA BM 702 A R01 en

8.4 Antenna selection

The graph below shows which antenna to select for the application.

Graph of tank height / measuring range against dielectric constant ε

r

Figure 8-2: Selection of antenna

a = tank height / measuring range [ft / m]
b = ε

r

for storage tanks with smooth product surface

c = ε

r

for process tanks or foam

d = ε

r

for agitator tanks with vortex

1 Stilling well* (not for agitator tanks)
2 Stilling well* (not for agitator tanks) or antenna type 4
3 Stilling well* (not for agitator tanks); Wave-Stick or antenna type 3 and type 4
4 Stilling well* (not for agitator tanks); antenna type 2, type 3 and type 4 or Wave-Stick
5 Stilling well* (not for agitator tanks) or Wave-Stick

* Stilling well is equal to Wave-Guide antenna and bypass chamber

.book Page 54 Thursday, September 3, 2009 2:53 PM