3.8.2 How to install a device with a threaded connection

Equipment needed:

• Device
• Gasket for G1½ or 1½NPT connection (not supplied)

• Make sure the tank connection is level.
• Make sure that you use the applicable gasket for the connection dimensions and the process.
• Make sure the tank connection is larger than the antenna.
• If the tank connection is smaller than the antenna, remove the antenna from the housing.

i

Either provide the means to adapt the device to a larger process connection on the tank (for
example, a plate with a slot), or use the same process connection, but remove the antenna
from the device before installation and attach it from inside the tank.

• Align the gasket correctly.
• Lower the antenna carefully into the tank.
• Turn the threaded connection on the housing to attach the device to the process connection.
• Tighten the connection.

i

Refer to local rules and regulations for the correct torque to apply to the connection.

• If the tank connection is smaller than the antenna, attach the antenna from inside the tank.

Requirements for threaded connections

Figure 3-13: Threaded connection