3.6.2 Installation in stilling wells

Use a stilling well if:

• There is highly conductive foam in the tank.
• The liquid is very turbulent or agitated.
• There are too many other obstacles near to the area where you want to install the device.
• There is an applications with a tank with a floating roof.

Figure 3-6: Installation recommendations for stilling wells

1 Basic requirements for a stilling well
2 Recommendations for tanks that have no foam
3 Air circulation hole (max. Ø10 mm / 0.4")
4 Maximum level of the liquid
5 Liquid circulation holes (max. Ø10 mm / 0.4")
6 Distance between holes ≥ 50 mm / 2"
7 Clearance between the antenna and the wall of the stilling well ≤ 5 mm / 0.2"
8 Sudden change in well diameter ≤ 1 mm / 0.04"

CAUTION!

Installation requirements

The stilling well must be electrically conductive.

The inside diameter of the stilling well must not be more than 10 mm / 0.4" over the diameter
of the antenna.

The stilling well must be straight.

The stilling well must have a surface roughness of ±≤0.1 mm / 0.004" or better.

There must be no sudden changes in internal diameter greater than 1 mm / 0.04".