8.3 Pressure ratings
V96 flange system with horn antenna or Wave-Guide:
max. allowable operating pressure
Approvals and certifications
CE
This device fulfils the statutory requirements of the EC directives.
The manufacturer certifies successful testing of the product by applying the CE
marking.
ATEX
ATEX II 1/2 G Ex ia IIC T6...T1
ATEX Directive 94/9/EC: EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007
Other standards and approvals
Other standards and approvals
Other standards and approvals
Other standards and approvals
EMC
EMC Directive 2004/108/EC: EN 61326-2-3:2006
R&TTE
R&TTE Directive 1995/5/EC: EN 302 372-2 V1.1.1
1 HART® is a registered trademark of the HART Communication Foundation.
Nominal
diameter
Flange rated pressure
PN16
PN25
PN40
PN64
DN
inches
bar
psig
bar
psig
bar
psig
bar
psig
80
3
16
232
-
-
40
580
64
928
100
4
16
232
-
-
38
551
55
797
150
6
16
232
-
-
34
493
47
681
200
8
16
232
25
362
32
464
45
652
Wave-Stick with flange plate: pressure / temperature rating
1 Pressure in [bar] or [psig]
2 Temperature in [°C] or [°F]
.book Page 53 Thursday, September 3, 2009 2:53 PM