beautypg.com

Technical data, 3 pressure ratings – KROHNE BM 702 A EN User Manual

Page 53

background image

TECHNICAL DATA

8

53

BM 702 A

www.krohne.com

09/2009 - 4000643301 - MA BM 702 A R01 en

8.3 Pressure ratings

V96 flange system with horn antenna or Wave-Guide:
max. allowable operating pressure

Approvals and certifications

CE

This device fulfils the statutory requirements of the EC directives.

The manufacturer certifies successful testing of the product by applying the CE

marking.

ATEX

ATEX II 1/2 G Ex ia IIC T6...T1

ATEX Directive 94/9/EC: EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007

Other standards and approvals

Other standards and approvals

Other standards and approvals

Other standards and approvals

EMC

EMC Directive 2004/108/EC: EN 61326-2-3:2006

R&TTE

R&TTE Directive 1995/5/EC: EN 302 372-2 V1.1.1

1 HART® is a registered trademark of the HART Communication Foundation.

Nominal

diameter

Flange rated pressure

PN16

PN25

PN40

PN64

DN

inches

bar

psig

bar

psig

bar

psig

bar

psig

80

3

16

232

-

-

40

580

64

928

100

4

16

232

-

-

38

551

55

797

150

6

16

232

-

-

34

493

47

681

200

8

16

232

25

362

32

464

45

652

Wave-Stick with flange plate: pressure / temperature rating

1 Pressure in [bar] or [psig]
2 Temperature in [°C] or [°F]

.book Page 53 Thursday, September 3, 2009 2:53 PM