beautypg.com

Installation – KROHNE BM 702 A EN User Manual

Page 27

background image

INSTALLATION

3

27

BM 702 A

www.krohne.com

09/2009 - 4000643301 - MA BM 702 A R01 en

3.8.3 Field assembly

In general all device versions are delivered in fully assembled condition. However ia a device
should be delivered in parts, or parts are subsequently replaced, the following provedure should
be noted.

• Bolt the Wave-Guide window (flange mount) or distance piece 3, if supplied loose, to the

device.

• Torque for the sets of 4 Allen screws M

M

M

M (key size 5 mm) is max. 8 Nm / 5.8 ft lbf.

Caution: Ensure the upper Teflon

®

plug 4 is kept absolutely dry and clean! Moisture and dirt

will impair the functionality of the device!

• Bolt antenna extension 7 to the antenna 8.
• Torque for the 3 stud bolts A

A

A

A is max. 8 Nm / 5.8 ft lbf.

Caution: Do not detach bolts H

H

H

H!

INFORMATION!
For any necessary field assembly all parts are included with the delivery (stud bolts, washers,
etc.).

Figure 3-14: Field assembly of device

1 Signal converter
2 O-ring
3 Distance piece for high-temperature version (option)
4 Upper Teflon

®

plug

5 Lower Teflon

®

plug

6 Antenna
7 Antenna extension (option)
8 Connecting flange of device

.book Page 27 Thursday, September 3, 2009 2:53 PM