TECHNICAL DATA

72

OPTITEMP TRA/TCA PLUS

www.krohne.com

01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01

7.7 Permissible temperatures

7.7.1 Connection head

7.7.2 Unloaded thermowell and immersion tubes

The temperatures specified in the following tables are valid only for thermowells and immersion
tubes that do not project into flowing media or media under pressure. The maximum permissible
temperature is reduced under load.

Thermowells

Sheaths of measuring inserts made of mineral insulated cable

Temperature
transmitter

Connection head

Temperature range Maximum temperature

limiting component

Material

Display

without

Metal

no

-40...+100°C /

-40...+212°F

Gasket of connection head

cover and cable gland

without

Plastic

no

-40...+80°C /

-40...+176°F

Connection head material

with

Metal

no

-40...+85°C /

-40...+185°F

Temperature transmitter

with

Plastic

no

-40...+80°C /

-40...+176°F

Connection head material

with

Metal

Yes

-40...+70°C /

-40...+158°F

Display

DANGER!
If you are unsure as to whether the device can withstand the loads of the process when using an
insertion-type thermometer without thermowell, have a separate strength calculation done (e.g.
per DITTRICH or MURDOCK, ASME PTC 10.9-TW)! For further information contact the
manufacturer.

INFORMATION!
The manufacturer can provide an optional strength calculation for a fee.

Type of
thermowell

Material

Permissible temperature range

-T30

1.4571 / AISI 316 Ti

-200...+600°C / -328...+1112°F

1.4404 / AISI 316 L

-200...+600°C / -328...+1112°F

1.7335 / AISI F12

-200...+550°C / -328...+1022°F

1.0460 / C22.8

-200...+550°C / -328...+1022°F

All others

1.4571 / AISI 316 Ti

-200...+600°C / -328...+1112°F

1.4404 / AISI 316 L

-200...+600°C / -328...+1112°F

Type of sensor

Cable jacket material

Permissible temperature range

Pt100 RTD

1.4404 / AISI 316 L

-200...+600°C / -328...+1112°F

Thermocouple

Inconel

®

600

-40...+1100°C / -40...+1832°F

.backup.book Page 72 Tuesday, January 10, 2012 11:57 AM