INSTALLATION

3

31

OPTITEMP TRA/TCA PLUS

www.krohne.com

01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01

The second diagram applies to thermometer(s):

• TRA/TCA-TS36 (Form 6 and 7)
• Ø 17 x 5 mm / 0.67 x 0.20"
• Material 1.4571 / 316 Ti

Figure 3-4: Load diagram for TRA/TCA-TS36

1 Pressure of the measured medium
2 Steam pressure curve
3 Steam
4 Water
5 Insertion length 230 mm or 9.06"; water with 3 m/s or 9.8 ft/s
6 Insertion length 230 mm or 9.06"; steam with 40 m/s or 131.2 ft/s
7 Insertion length 230 mm or 9.06"; air with 40 m/s or 131.2 ft/s
8 Temperature of the measured medium

40

80

120

160

200

240

280

320

400

360