TECHNICAL DATA

7

45

OPTITEMP TRA/TCA PLUS

www.krohne.com

01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01

7.2 Technical data tables

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local representative.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range

Measuring the temperature of gases, liquids, vapours and solid

bodies in industrial processes with advanced requirements (e.g. high

pressure and high flow velocities).

Measuring principle

Contact thermometer

Measured value

Temperature

Design

Modular design

Industrial thermometers for advanced requirements consist of

several components which, together, form a thermometer assembly:

Measuring insert with temperature sensor

Transmitter (either inside on the measuring insert or outside)

Connection head

Separate neck tube

Thermowell

Signal converter

Analogue or digital temperature transmitter in the TT family as head-

mount or rail-mount transmitter.

Sensor

Pt100 RTD as thin layer variant (TF) or as wire wound variant (WW)

with a characteristic according to DIN EN 60751.

Type "J" or "K" thermocouple with a characteristic according to

DIN EN 60584.

Measuring range

Refer to "Operating conditions".

Display and user interface

Display and user interface

Display and user interface

Display and user interface

Display

Only in connection head "BUZ-HW": 4...20 mA, non-illuminated, LCD,

loop powered indicator.

Operation

Only in connection head "BUZ-HW": interior keys.

Display functions

Temperature, either as output signal (HART

®

penetrable) in mA or

scaled to °C/°F.