TECHNICAL DATA

7

65

OPTITEMP TRA/TCA PLUS

www.krohne.com

01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01

7.5 Process connections

Threaded thermometer without thermowell

Threaded thermometer with thermowell

Flange thermometer

Weld-in thermometer

Process connection

Materials

Ø of neck tube

[mm]

["]

Thread M18 x 1.5 mm

1.4571

12 x 2.5

0.47 x 0.1

Thread G½", G¾"

Union nut G½", G¾"

Thread ½" NPT (NN and NUN)

1.4404

21.34 x 2.77

0.84 x 0.11 SCH 40

Process connection

Materials

Ø of thermowell

[mm]

["]

Thread G½", G¾"

1.4571 / AISI 316 Ti,

1.4404 / AISI 316 L

9, 10, 11, 12, 6, 17,

22

0.35, 0.39, 0.43, 0.47,

0.63, 0.67, 0.87

Thread ½" NPT, ¾" NPT

Process connection

Materials

Ø of thermowell

[mm]

["]

DN25 / PN40

1.4571 / AISI 316 Ti,

1.4404 / AISI 316 L

9, 10, 11, 12, 19, 22,

23, 25

0.35, 0.39, 0.43, 0.47,

0.75, 0.87, 0.98

DN50 / PN40

1" / 150 lb, 300 lb, 600 lb

1½" / 150 lb, 300 lb, 600 lb

2" / 150 lb, 300 lb, 600 lb

INFORMATION!
The manufacturer offers the flange thermometer with process connections acc. to DIN EN 1092-
1 or ASME/ANSI 16.5. For DIN flanges the raised face complies with Form B1 and with ASME
flanges, type "RF" or type "RTJ".

Ø at the weld-in point

Materials

Ø of thermowell

[mm]

["]

[mm]

["]

24 h7

0.94

1.4571 / AISI 316 Ti,

1.4404 / AISI 316 L,

1.7335 / AISI F12,

1.0460 / C 22.8

24 h7

0.94

26.7

1.05

1.4571 / AISI 316 Ti,

1.4404 / AISI 316 L

19

0.75

33.4

1.31

1.4571 / AISI 316 Ti,

1.4404 / AISI 316 L

23, 25

0.91, 0.98

.backup.book Page 65 Tuesday, January 10, 2012 11:57 AM