3

INSTALLATION

30

OPTITEMP TRA/TCA PLUS

www.krohne.com

01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01

The first diagram applies to thermometer(s):

• TRA/TCA-T30 (Form 4)
• Ø 24 x 8.5 mm / 0.94 x 0.33"
• Material 1.4571 / 316 Ti

Figure 3-3: Load diagram for TRA/TCA-T30

1 Pressure of the measured medium
2 Steam pressure curve
3 Steam
4 Water
5 Insertion length 125 mm or 4.92"; water with 5 m/s or 16.4 ft/s
6 Insertion length 125 mm or 4.92"; steam with 60 m/s or 196.9 ft/s
7 Insertion length 125 mm or 4.92"; air with 60 m/s or 196.9 ft/s
8 Temperature of the measured medium

.backup.book Page 30 Tuesday, January 10, 2012 11:57 AM