7
TECHNICAL DATA
52
OPTITEMP TRA/TCA PLUS
www.krohne.com
01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01
TRA/TCA-S34 with DIN-neck tube (neck tube length: 165 mm / 6.5")
Insertion length "b"
Measuring insert length
[mm]
["]
[mm]
["]
100
3.9
278
10.9
140
5.5
318
12.5
200
7.9
378
14.9
260
10.2
438
17.2
300
11.8
478
18.8
350
13.8
528
20.8
400
15.8
578
22.8
TRA/TCA-S50 with ASME-neck tube (neck tube length: 152 mm / 6.0")
Insertion length "b"
Measuring insert length
[mm]
["]
[mm]
["]
100
3.9
281
11.1
150
5.9
331
13.0
200
7.9
381
15.0
250
9.8
431
17.0
300
11.8
481
18.9
350
13.8
531
20.9
400
15.7
581
22.9
INFORMATION!
You can determine the length of the measuring insert for threaded thermometers without
thermowell as follows:
•
TRA/TCA-S34 with DIN neck tube: Measuring insert length = insertion length of the
thermometer assembly + 178 mm / 7.0"
•
TRA/TCA-S50 with ASME neck tube: Measuring insert length = insertion length of
thermometer assembly + 181 mm / 7.1"
INFORMATION!
•
Tolerances of all thermowell and insertion lengths: ±1 mm / 0.04"
•
Tolerances of all measuring insert lengths: +2 mm, -0 mm / +0.08", -0"
.backup.book Page 52 Tuesday, January 10, 2012 11:57 AM
- BATCHFLUX 5500 C Quickstart EN (20 pages)
- IFC 050 Converter Quickstart EN (28 pages)
- IFC 100 Converter Quickstart EN (32 pages)
- IFC 300 Converter Quickstart EN (68 pages)
- OPTIFLUX 1000 Quickstart EN (20 pages)
- OPTIFLUX 2000 Quickstart EN (24 pages)
- OPTIFLUX 4000 Quickstart EN (24 pages)
- OPTIFLUX 4040C Quickstart EN (16 pages)
- OPTIFLUX 5000 Flange Quickstart EN (20 pages)
- OPTIFLUX 5000 Sandwich Quickstart EN (20 pages)
- OPTIFLUX 6000 Quickstart EN (28 pages)
- OPTIFLUX 7300 Quickstart EN (24 pages)
- OPTIPROBE Quickstart EN (16 pages)
- TIDALFLUX 2300 F EN (44 pages)
- TIDALFLUX 2300 F Quickstart EN (24 pages)
- WATERFLUX 3000 EN (40 pages)
- WATERFLUX 3000 Quickstart EN (24 pages)
- WATERFLUX 3070 EN (80 pages)
- WATERFLUX 3070 Quickstart EN (32 pages)
- USB ADAPTER PLUS EMF EN (16 pages)
- IFC 050 Converter Modbus EN (20 pages)
- IFC 100 Converter FOUNDATION FIELDBUS EN (64 pages)
- IFC 100 Converter Modbus EN (20 pages)
- IFC 300 Converter FOUNDATION FIELDBUS EN (60 pages)
- IFC 300 Converter HART 0102 EN (20 pages)
- IFC 300 Converter HART 0201 EN (23 pages)
- IFC 300 Converter Modbus EN (24 pages)
- IFC 300 Converter PROFIBUS PA DP EN (40 pages)
- OPTIFLUX 2000-4000 IECEx EN (16 pages)
- OPTIFLUX 2000-4000-5000-6000-7300-IFC 300 Ex EN (40 pages)
- OPTIFLUX 2000-4000-5000-6000 -IFC 100 Ex EN (24 pages)
- OPTIFLUX 4040 C Ex EN (20 pages)
- OPTIFLUX x300 Ex Zone2 EN (1 page)
- H250 M9 ES EN (36 pages)
- VA 40-VA 45 EN (36 pages)
- H250 M10 ATEX II2G Ex d EN (16 pages)
- H250 M10 ATEX II3D Ex t EN (16 pages)
- H250 M40 ATEX II2D Ex t-II2G Ex d EN (20 pages)
- H250 M40 ATEX II2G Ex i EN (20 pages)
- H250 M40 ATEX II3G Ex nA EN (20 pages)
- H250 M40 Ex II2G Reed EN (2 pages)
- H250 M9 ATEX II2G Ex i EN (16 pages)
- H250 M9S ATEX II3D Ex t-II3G Ex nA EN (20 pages)
- M8E Converter HART 0101 EN (13 pages)
- DK 32-DK 34 ATEX II2G Ex i EN (16 pages)