TECHNICAL DATA

52

OPTITEMP TRA/TCA PLUS

www.krohne.com

01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01

TRA/TCA-S34 with DIN-neck tube (neck tube length: 165 mm / 6.5")

Insertion length "b"

Measuring insert length

[mm]

["]

[mm]

["]

100

3.9

278

10.9

140

5.5

318

12.5

200

7.9

378

14.9

260

10.2

438

17.2

300

11.8

478

18.8

350

13.8

528

20.8

400

15.8

578

22.8

TRA/TCA-S50 with ASME-neck tube (neck tube length: 152 mm / 6.0")

Insertion length "b"

Measuring insert length

[mm]

["]

[mm]

["]

100

3.9

281

11.1

150

5.9

331

13.0

200

7.9

381

15.0

250

9.8

431

17.0

300

11.8

481

18.9

350

13.8

531

20.9

400

15.7

581

22.9

INFORMATION!
You can determine the length of the measuring insert for threaded thermometers without
thermowell as follows:

TRA/TCA-S34 with DIN neck tube: Measuring insert length = insertion length of the
thermometer assembly + 178 mm / 7.0"

TRA/TCA-S50 with ASME neck tube: Measuring insert length = insertion length of
thermometer assembly + 181 mm / 7.1"

INFORMATION!

Tolerances of all thermowell and insertion lengths: ±1 mm / 0.04"

Tolerances of all measuring insert lengths: +2 mm, -0 mm / +0.08", -0"

.backup.book Page 52 Tuesday, January 10, 2012 11:57 AM