Technical data – KROHNE OPTITEMP TRA-TCA Plus EN User Manual
Page 68

7
TECHNICAL DATA
68
OPTITEMP TRA/TCA PLUS
www.krohne.com
01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01
7.6.3 Operating limits for one-piece, conical bar stock thermowells
TRA/TCA-TS53 with Ø 16 to 13 mm / 0.63 to 0.51"
TRA/TCA-TS53 with Ø 22 to 16 mm / 0.87 to 0.63"
TRA/TCA-TF56 with Ø 22 to 16 mm / 0.87 to 0.63"
Process connection
Material
Insertion length p
max
at +20°C / +400°C or
+68°F / +752°F, air
p
max
at +20°C / +400°C or
+68°F / +752°F, water /
vapour
[mm]
["]
[bar]
[psi]
[bar]
[psi]
Thread G½", G¾",
½
" NPT, ¾" NPT
1.4571 /
316 Ti,
1.4404 /
316 L
100
3.9
100 / 100
1450 / 1450
100 / 100
1450 / 1450
300
11.8
50.0 / 62.8
725 / 910
100 / 100
1450 / 1450
Process connection
Material
Insertion length p
max
at +20°C / +400°C or
+68°F / +752°F, air
p
max
at +20°C / +400°C or
+68°F / +752°F, water /
vapour
[mm]
["]
[bar]
[psi]
[bar]
[psi]
Thread G½", G¾",
½
" NPT, ¾" NPT
1.4571 /
316 Ti,
1.4404 /
316 L
100
3.9
100 / 100
1450 / 1450
100 / 100
1450 / 1450
300
11.8
100 / 100
1450 / 1450
100 / 100
1450 / 1450
Process connection
Material
Insertion length p
max
at +20°C / +400°C or
+68°F / +752°F, air
p
max
at +20°C / +400°C or
+68°F / +752°F, water /
vapour
[mm]
["]
[bar]
[psi]
[bar]
[psi]
Flanges ASME 1",
1½", 2" 150 lb
1.4404 /
316 L
100
3.9
15.9 / 6.5
231 / 94
15.9 / 6.5
231 / 94
300
11.8
15.9 / 6.5
231 / 94
15.9 / 6.5
231 / 94
Flanges ASME 1",
1½", 2" 300 lb
100
3.9
41.4 / 24.3
600 / 352
41.4 / 24.3
600 / 352
300
11.8
41.4 / 24.3
600 / 352
41.4 / 24.3
600 / 352
Flanges ASME 1",
1½", 2" 600 lb
100
3.9
82.7 / 48.6
1199 / 705
82.7 / 48.6
1199 / 705
300
11.8
82.7 / 48.6
1199 / 705
82.7 / 48.6
1199 / 705
Flanges DN25, DN50
PN40
100
3.9
40.0 / 25.7
580 / 373
40.0 / 25.7
580 / 373
300
11.8
40.0 / 25.7
580 / 373
40.0 / 25.7
580 / 373
.backup.book Page 68 Tuesday, January 10, 2012 11:57 AM